Performance and reliability of a high efficiency flat plate collector - Final results on prototypes

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/4493
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/4533
dc.contributor.author Föste, Sebastian
dc.contributor.author Giovannetti, Federico
dc.contributor.author Ehrmann, Nicole
dc.contributor.author Rockendorf, Gunter
dc.date.accessioned 2019-03-06T09:48:59Z
dc.date.available 2019-03-06T09:48:59Z
dc.date.issued 2014
dc.identifier.citation Föste, S.; Giovannetti, F.; Ehrmann, N.; Rockendorf, G.: Performance and reliability of a high efficiency flat plate collector - Final results on prototypes. In: Energy Procedia 48 (2014), S. 48-57. DOI: https://doi.org/10.1016/j.egypro.2014.02.007
dc.description.abstract The paper presents the final results of our prototype investigations regarding the performance and reliability of a high efficiency flat plate collector with a gas-filled low-e double-glazing as transparent cover. The measured efficiency of an optimized prototype results in an increase in efficiency of 70 % at a temperature difference of 60 K (G = 500 W/m2) compared to a standard flat plate collector. The effect of additional antireflecting coatings and different gas fillings of the glazing is analyzed by prototype measurements. As the heat losses of the collector are significantly reduced by the low-e glazing, a stagnation temperature of 265 °C was determined at the absorber plate experimentally. The collector components have to withstand these increased temperature loads. Test and assessment methods for the long term stability of the hermetically sealed double-glazing against high temperatures and the combination of temperature and UV-radiation were developed and performed successfully. Further, the reliability of four prototype collectors was confirmed by a one-year outdoor-exposure test. A simplified economic analysis resulted in an optimum operating range for the collector of 80 °C to 110 °C compared to commercially available flat plate and evacuated tube collectors. As the main result of the research project, a new flat plate collector with a significantly increased performance and an experimentally proved reliability was developed up to a prototype status, which can be transferred to industrial production. eng
dc.language.iso eng
dc.publisher London : Elsevier Ltd.
dc.relation.ispartofseries Energy Procedia 48 (2014)
dc.rights CC BY-NC-ND 3.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/3.0/
dc.subject Aluminum zinc oxide eng
dc.subject Collector efficiency eng
dc.subject Flat plate collector eng
dc.subject Indium tin oxide eng
dc.subject Low emitting coating eng
dc.subject Low-e eng
dc.subject.classification Konferenzschrift ger
dc.subject.ddc 620 | Ingenieurwissenschaften und Maschinenbau ger
dc.title Performance and reliability of a high efficiency flat plate collector - Final results on prototypes
dc.type Article
dc.type Text
dc.relation.issn 1876-6102
dc.relation.doi https://doi.org/10.1016/j.egypro.2014.02.007
dc.bibliographicCitation.volume 48
dc.bibliographicCitation.firstPage 48
dc.bibliographicCitation.lastPage 57
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

  • An-Institute
    Frei zugängliche Publikationen aus An-Instituten der Leibniz Universität Hannover