Deceleration, precooling, and multi-pass stopping of highly charged ions in Be+ Coulomb crystals

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/3078
dc.identifier.uri http://www.repo.uni-hannover.de/handle/123456789/3108
dc.contributor.author Schmöger, L.
dc.contributor.author Schwarz, M.
dc.contributor.author Baumann, T.M.
dc.contributor.author Versolato, O.O.
dc.contributor.author Piest, B.
dc.contributor.author Pfeifer, T.
dc.contributor.author Ullrich, J.
dc.contributor.author Schmidt, Piet O.
dc.contributor.author Crespo López-Urrutia, J.R.
dc.date.accessioned 2018-04-11T10:45:15Z
dc.date.available 2018-04-11T10:45:15Z
dc.date.issued 2015
dc.identifier.citation Schmöger, L.; Schwarz, M.; Baumann, T.M.; Versolato, O.O.; Piest, B. et al.: Deceleration, precooling, and multi-pass stopping of highly charged ions in Be+ Coulomb crystals. In: Review of Scientific Instruments 86 (2015), Nr. 10, 103111. DOI: https://doi.org/10.1063/1.4934245
dc.description.abstract Preparing highly charged ions (HCIs) in a cold and strongly localized state is of particular interest for frequency metrology and tests of possible spatial and temporal variations of the fine structure constant. Our versatile preparation technique is based on the generic modular combination of a pulsed ion source with a cryogenic linear Paul trap. Both instruments are connected by a compact beamline with deceleration and precooling properties. We present its design and commissioning experiments regarding these two functionalities. A pulsed buncher tube allows for the deceleration and longitudinal phase-space compression of the ion pulses. External injection of slow HCIs, specifically Ar13+, into the linear Paul trap and their subsequent retrapping in the absence of sympathetic cooling is demonstrated. The latter proved to be a necessary prerequisite for the multi-pass stopping of HCIs in continuously laser-cooled Be+ Coulomb crystals. © 2015 AIP Publishing LLC. eng
dc.language.iso eng
dc.publisher College Park, MD : American Institute of Physics
dc.relation.ispartofseries Review of Scientific Instruments 86 (2015), Nr. 10
dc.rights Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden.
dc.subject Charged particles eng
dc.subject Ion sources eng
dc.subject Laser cooling eng
dc.subject Phase space methods eng
dc.subject Fine structure constants eng
dc.subject Frequency metrology eng
dc.subject Highly charged ions eng
dc.subject Linear Paul Trap eng
dc.subject Preparation technique eng
dc.subject Pulsed ion sources eng
dc.subject Spatial and temporal variation eng
dc.subject Sympathetic cooling eng
dc.subject Cooling eng
dc.subject.ddc 530 | Physik ger
dc.title Deceleration, precooling, and multi-pass stopping of highly charged ions in Be+ Coulomb crystals eng
dc.type Article
dc.type Text
dc.relation.issn 00346748
dc.relation.doi https://doi.org/10.1063/1.4934245
dc.bibliographicCitation.issue 10
dc.bibliographicCitation.volume 86
dc.bibliographicCitation.firstPage 103111
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):