A Thermal-Hydraulic Model for the Stagnation of Solar Thermal Systems with Flat-Plate Collector Arrays

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/15723
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/15847
dc.contributor.author Eismann, Ralph
dc.contributor.author Hummel, Sebastian
dc.contributor.author Giovannetti, Federico
dc.date.accessioned 2023-12-12T08:31:45Z
dc.date.available 2023-12-12T08:31:45Z
dc.date.issued 2021
dc.identifier.citation Eismann, R.; Hummel, S.; Giovannetti, F.: A Thermal-Hydraulic Model for the Stagnation of Solar Thermal Systems with Flat-Plate Collector Arrays. In: Energies 14 (2021), Nr. 3, 733. DOI: https://doi.org/10.3390/en14030733
dc.description.abstract Stagnation is the transient state of a solar thermal system under high solar irradiation where the useful solar gain is zero. Both flat-plate collectors with selective absorber coatings and vacuum-tube collectors exhibit stagnation temperatures far above the saturation temperature of the glycol-based heat carriers within the range of typical system pressures. Therefore, stagnation is always associated with vaporization and propagation of vapor into the pipes of the solar circuit. It is therefore essential to design the system in such a way that vapor never reaches components that cannot withstand high temperatures. In this article, a thermal-hydraulic model based on the integral form of a two-phase mixture model and a drift-flux correlation is presented. The model is applicable to solar thermal flat-plate collectors with meander-shaped absorber tubes and selective absorber coatings. Experimental data from stagnation experiments on two systems, which are identical except for the optical properties of the absorber coating, allowed comparison with simulations carried out under the same boundary conditions. The absorber of one system features a conventional highly selective coating, while the absorber of the other system features a thermochromic coating, which exhibits a significantly lower stagnation temperature. Comparison of simulation results and experimental data shows good conformity. This model is implemented into an open-source software tool called THD for the thermal-hydraulic dimensioning of solar systems. The latest version of THD, updated by the results of this article, enables planners to achieve cost-optimal design of solar thermal systems and to ensure failsafe operation by predicting the steam range under the initial and boundary conditions of worst-case scenarios. eng
dc.language.iso eng
dc.publisher Basel : MDPI
dc.relation.ispartofseries Energies 14 (2021), Nr. 3
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0
dc.subject Flat-plate collector eng
dc.subject Solar thermal eng
dc.subject Stagnation eng
dc.subject Steam range eng
dc.subject Thermal-hydraulic model eng
dc.subject Two-phase mixture model eng
dc.subject.ddc 620 | Ingenieurwissenschaften und Maschinenbau
dc.title A Thermal-Hydraulic Model for the Stagnation of Solar Thermal Systems with Flat-Plate Collector Arrays eng
dc.type Article
dc.type Text
dc.relation.essn 1996-1073
dc.relation.doi https://doi.org/10.3390/en14030733
dc.bibliographicCitation.issue 3
dc.bibliographicCitation.volume 14
dc.bibliographicCitation.firstPage 733
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

  • An-Institute
    Frei zugängliche Publikationen aus An-Instituten der Leibniz Universität Hannover