Calibration-measurement unit for the automation of vector network analyzer measurements

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/1455
dc.identifier.uri http://www.repo.uni-hannover.de/handle/123456789/1480
dc.contributor.author Rolfes, I.
dc.contributor.author Will, B.
dc.contributor.author Schiek, B.
dc.date.accessioned 2017-05-09T12:13:45Z
dc.date.available 2017-05-09T12:13:45Z
dc.date.issued 2008
dc.identifier.citation Rolfes, I.; Will, B.; Schiek, B.: Calibration-measurement unit for the automation of vector network analyzer measurements. In: Advances in Radio Science 6 (2008), S. 27-30. DOI: https://doi.org/10.5194/ars-6-27-2008
dc.description.abstract With the availability of multi-port vector network analyzers, the need for automated, calibrated measurement facilities increases. In this contribution, a calibrationmeasurement unit is presented which realizes a repeatable automated calibration of the measurement setup as well as a user-friendly measurement of the device under test (DUT). In difference to commercially available calibration units, which are connected to the ports of the vector network analyzer preceding a measurement and which are then removed so that the DUT can be connected, the presented calibrationmeasurement unit is permanently connected to the ports of the VNA for the calibration as well as for the measurement of the DUT. This helps to simplify the calibrated measurement of complex scattering parameters. Moreover, a full integration of the calibration unit into the analyzer setup becomes possible. The calibration-measurement unit is based on a multiport switch setup of e.g. electromechanical relays. Under the assumption of symmetry of a switch, on the one hand the unit realizes the connection of calibration standards like one-port reflection standards and two-port through connections between different ports and on the other hand it enables the connection of the DUT. The calibration-measurement unit is applicable for two-port VNAs as well as for multiport VNAs. For the calibration of the unit, methods with completely known calibration standards like SOLT (short, open, load, through) as well as self-calibration procedures like TMR or TLR can be applied. © Author(s) 2008. eng
dc.language.iso eng
dc.publisher Göttingen : Copernicus GmbH
dc.relation.ispartofseries Advances in Radio Science 6 (2008)
dc.rights CC BY 3.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/3.0/
dc.subject Automated calibration eng
dc.subject Calibration standard eng
dc.subject Complex scattering parameters eng
dc.subject Device under test eng
dc.subject Electromechanical relays eng
dc.subject Multiport switches eng
dc.subject Self-calibration procedures eng
dc.subject Vector network analyzers eng
dc.subject Calibration eng
dc.subject Design for testability eng
dc.subject Scattering parameters eng
dc.subject Standards eng
dc.subject Units of measurement eng
dc.subject Electric network analyzers eng
dc.subject.ddc 621,3 | Elektrotechnik, Elektronik ger
dc.title Calibration-measurement unit for the automation of vector network analyzer measurements eng
dc.type Article
dc.type Text
dc.relation.issn 1684-9965
dc.relation.doi https://doi.org/10.5194/ars-6-27-2008
dc.bibliographicCitation.volume 6
dc.bibliographicCitation.firstPage 27
dc.bibliographicCitation.lastPage 30
dc.description.version publishedVersion
tib.accessRights frei zug�nglich