Abstract: 
Temperature sensors and heaters belong in the diagnostics subsystem of the LISA Technology Package (LTP) on board LISA Pathfinder, the technology demonstrator for LISA. A number of these diagnostics items are placed at short distances from the LTP proof masses, and are negative temperature coefficient (NTC) thermistors. By design, these devices have tiny amounts of ferromagnetic materials which therefore constitute a potential source of disturbance to the performance of the LTP. We present a detailed magnetic characterisation of the NTC's, and use the data to evaluate their impact on the acceleration noise budget of the LTP. The effect is seen to be small, and can be further reduced if the NTC's are submitted to a demagnetisation process before they are attached. Re-magnetisation is unlikely, as rather strong fields (mili-Tesla) are required to re-magnetise the NTC's.
License of this version: CC BY 3.0 Unported
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2009
Appears in Collections:An-Institute

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of United States United States 26 35.14%
2 image of flag of Germany Germany 24 32.43%
3 image of flag of China China 16 21.62%
4 image of flag of France France 2 2.70%
5 image of flag of Europe Europe 2 2.70%
6 image of flag of Taiwan Taiwan 1 1.35%
7 image of flag of Thailand Thailand 1 1.35%
8 image of flag of Hong Kong Hong Kong 1 1.35%
9 image of flag of Austria Austria 1 1.35%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse