Subsystems for all-optical coherent quantum-noise cancellation

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/9179
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/9232
dc.contributor.author Steinmeyer, Daniel ger
dc.date.accessioned 2020-01-06T10:28:37Z
dc.date.available 2020-01-06T10:28:37Z
dc.date.issued 2019
dc.identifier.citation Steinmeyer, Daniel: Subsystems for all-optical coherent quantum-noise cancellation. Hannover : Gottfried Wilhelm Leibniz Universität, Diss., 2019, xv, 245 S. DOI: https://doi.org/10.15488/9179 ger
dc.description.abstract Quantum mechanics dictates that a measurement always disturb the measured system. In weak continuous measurements, the trade-off between measurement precision and back-action onto the system yields an optimal measurement sensitivity, which is known as the Standard Quantum Limit (SQL) in opto-mechanical measurements, such as gravitational-wave detection. It corresponds to finding the optimal optical power in a compromise between quantum shot noise and quantum radiation-pressure noise. Coherent quantum-noise cancellation (CQNC) aims at overcoming the SQL and reducing back-action noise via the introduction of an effective negative-mass oscillator. In an alloptical set-up, this oscillator is realised by a detuned optical resonator coupled to incoming light with a beam-splitter and a down-conversion interaction and needs to be matched to the measured system in resonance frequency, damping and coupling strengths. This thesis explores the nature of CQNC and a potential all-optical realisation in theory and experiment, with a particular emphasis on the beam-splitter and the down-conversion interaction. Two possible set-ups are compared theoretically and critical parameters determined. Available opto-mechanical devices were characterised and confirmed to be suitable for CQNC. The down-conversion coupling strength gDC is linked to experimentally obtainable parameters. More than 2.3 dB reduction in uncertainty of two-mode squeezed light were observed. The squeezing measurements yielded gDC = 2\pi\times200 kHz at 100mW pump power, which is well within the initially required range and is in agreement with results from two other measurement methods. Optical resonators coupled via a beam-splitter interaction are studied theoretically and experimentally. In this work, the beam-splitter interaction of strength gBS was realised by a wave plate. A simplified experiment design enabled stabilisation of the coupled resonators. Our experimental observations accurately confirmed our theoretical predictions. The observed mode splitting yielded gBS = 2\pi\times235 kHz, within the updated requirements. Losses and a limited measurement strength will be the limiting factors for CQNC. The updated set of parameters, backed by the conducted experiments, paves the way towards a reduction of radiation-pressure noise of up to 4.8 dB. ger
dc.language.iso eng ger
dc.publisher Hannover : Institutionelles Repositorium der Leibniz Universität Hannover
dc.rights CC BY 3.0 DE ger
dc.rights.uri http://creativecommons.org/licenses/by/3.0/de/ ger
dc.subject coherent quantum-noise cancellation eng
dc.subject standard quantum limit eng
dc.subject two-mode squeezed light eng
dc.subject coupled optical resonators eng
dc.subject kohärente Quantenrauschunterdrückung ger
dc.subject Standardquantenlimit ger
dc.subject zwei-Moden-gequetschtes Licht ger
dc.subject gekoppelte optische Resonatoren ger
dc.subject.ddc 530 | Physik ger
dc.title Subsystems for all-optical coherent quantum-noise cancellation eng
dc.type DoctoralThesis ger
dc.type Text ger
dcterms.extent xv, 245 S.
dc.description.version publishedVersion ger
tib.accessRights frei zug�nglich ger