Browse Fakultät für Maschinenbau by Dewey Decimal Classification

Browse Fakultät für Maschinenbau by Dewey Decimal Classification

Sort by: Order: Results:

  • Richter, Berna I.; Ostermeier, Sven; Turger, Anke; Denkena, Berend; Hurschler, Christof (London : BioMed Central Ltd., 2010)
    Background: Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, ...
  • Beneke, Valerie; Küster, Fennja; Neehus, Anna-Lena; Hesse, Christina; Lopez-Rodriguez, Elena; Rafiei Hashtchin, Anna; Schott, Juliane Wilhelmine; Walter, Dorothee; Braun, Armin; Wolkers, Willem F.; Ackermann, Mania; Lachmann, Nico (London : Macmillan Publishers Ltd, 2018)
    Macrophages are key cells of the innate immune system and act as tissue resident macrophages (TRMs) in the homeostasis of various tissues. Given their unique functions and therapeutic use as well as the feasibility to ...
  • Ezechieli, Marco; Diekmann, Julia; Weizbauer, Andreas; Becher, Christoph; Willbold, Elmar; Helmecke, Patrick; Lucas, Arne; Schavan, Robert; Windhagen, Henning (London : SAGE Publications Ltd., 2014)
    Degradable magnesium alloys are promising biomaterials for orthopedic applications. The aim of this study was to evaluate the potential effects on both the synovial membrane (synovialis) and the synovial fluid (synovia) ...
  • Kobler, Jan-Philipp; Dhanasingh, Anandhan; Kiran, Raphael; Jolly, Claude; Ortmaier, Tobias (New York [u.a.] : Hindawi Publishing Corporation, 2015)
    To develop skills sufficient for hearing preservation cochlear implant surgery, surgeons need to performseveral electrode insertion trials in ex vivo temporal bones, thereby consuming relatively expensive electrode carriers. ...
  • Weizbauer, Andreas; Modrejewski, Christian; Behrens, Sabine; Klein, Helmut; Helmecke, Patrick; Seitz, Jan-Marten; Windhagen, Henning; Möhwald, Kai; Reifenrath, Janin; Waizy, Hazibullah (London : SAGE Publications Ltd., 2014)
    In this in vitro study, magnesium plates of ZEK100 and MgCa0.8 alloy similar to common titanium alloy osteosynthesis plates were investigated as degradable biomedical materials with a focus on primary stability. Immersion ...
  • Pressel, Thomas; Bouguecha, Anas; Vogt, Ute; Meyer-Lindenberg, Andrea; Behrens, Bernd-Arno; Nolte, Ingo; Windhagen, Henning (London : BioMed Central Ltd., 2005)
    After the publication of this work [1], we became aware of the fact that the frequency of the ultrasound transmitter that we used for determining the elastic moduli of the trabecular bone specimens was not correctly ...
  • Feser, K.; Kietzmann, M.; Bäumer, W.; Krause, C.; Bach, F.W. (London : SAGE Publications Ltd., 2011)
    Degradable magnesium alloys are new materials for implants used in orthopedic and trauma surgery. The aim of this study was to investigate the influence of degradable magnesium alloys on the function of dendritic cells ...
  • Erdmann, Nina; Bondarenko, Alexandr; Hewicker-Trautwein, Marion; Angrisani, Nina; Reifenrath, Janin; Lucas, Arne; Meyer-Lindenberg, Andrea (London : BioMed Central Ltd., 2010)
    Background: Recent studies have shown the potential suitability of magnesium alloys as biodegradable implants. The aim of the present study was to compare the soft tissue biocompatibility of MgCa0.8 and commonly used ...
  • Mohebbi, Saleh; Mirsalehi, Marjan; Kahrs, Lüder Alexander; Ortmaier, Tobias; Lenarz, Thomas; Majdani, Omid (Mashhad : Mashhad University of Medical Sciences, 2017)
    Introduction: Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may ...
  • Pogozhykh, Denys; Pakhomova, Y.; Pervushina, O.; Hofmann, Nicola; Glasmacher, Birgit; Zhegunov, G. (San Francisco, CA : Public Library of Science, 2017)
    Efficient application of veterinary blood transfusion approaches for small companion animals requires readily available supply of the donor material. This can be achieved by developing of effective biobanking technologies ...
  • Mohebbi, Saleh; Lexow, Jakob; Fuchs, Alexander; Rau, Thomas; Tauscher, Sebastian; Mirsalehi, Marjan; Hosseini, Seyed Mousa Sadr; Ortmaier, Tobias; Lenarz, Thomas; Majdani, Omid (Maschhad : Mashhad University of Medical Sciences, 2018)
    Introduction: Different approaches have been developed to find the position of the internal auditory canal (IAC) in middle cranial fossa approach. A feasibility study was performed to investigate the combination of cone ...
  • Van Drunen, Wouter Johannes; Mueller, Mathias; Glukhovskoy, Anatoly; Salcher, Rolf; Wurz, Marc Christopher; Lenarz, Thomas; Maier, Hannes (New York, NY : Hindawi Publishing Corporation, 2017)
    Introduction. Most implantable hearing aids currently available were developed to compensate the sensorineural hearing loss by driving middle ear structures (e.g., the ossicles). These devices are successfully used in round ...
  • Rohani, Pooyan; Pile, Jason; Kahrs, Lüder Alexander; Balachandran, Ramya; Blachon, Gregoire S.; Simaan, Nabil; Labadie, Robert F. (London : SAGE Publications Ltd., 2014)
    Objective. Minimally invasive image-guided cochlear implantation (CI) utilizes a patient-customized microstereotactic frame to access the cochlea via a single drill-pass. We investigate the average force and trauma associated ...
  • Fuchs, Julia; Mueller, Marc; Daxböck, Christine; Stückler, Manuela; Lang, Ingrid; Leitinger, Gerd; Bock, Elisabeth; El-Heliebi, Amin; Moser, Gerit; Glasmacher, Birgit; Brislinger, Dagmar (Heidelberg : Springer Verlag, 2018)
    Histological processing of thermosensitive electrospun poly(ε-caprolactone)/poly(l-lactide) (PCL/PLA) scaffolds fails, as poly(ε-caprolactone) (PCL) is characterized by its low-melting temperature (Tm = 60 °C). Here, we ...
  • Brand, Stephan; Bauer, Michael; Petri, Maximilian; Schrader, Julian; Maier, Hans Jürgen; Krettek, Christian; Hassel, Thomas (London : SAGE Publications Ltd., 2016)
    Treatment of periprosthetic femur fractures after total hip arthroplasty remains a major challenge in orthopedic surgery. Recently, a novel surgical technique using intraprosthetic screw fixation has been suggested. The ...
  • Waizy, Hazibullah; Weizbauer, Andreas; Modrejewski, Christian; Witte, Frank; Windhagen, Henning; Lucas, Arne; Kieke, Marc D.K.; Denkena, Berend; Behrens, Peter; Meyer-Lindenberg, Andrea; Bach, Friedrich-Wilhelm; Thorey, Fritz (London : BioMed Central Ltd., 2012)
    Background: In recent years magnesium alloys have been intensively investigated as potential resorbable materials with appropriate mechanical and corrosion properties. Particularly in orthopedic research magnesium is ...
  • Huehnerschulte, Tim Andreas; Reifenrath, Janin; Rechenberg, Brigitte von; Dziuba, Dina; Seitz, Jan-Marten; Bormann, Dirk; Windhagen, Henning; Meyer-Lindenberg, Andrea (London : BioMed Central Ltd, 2012)
    Background: Most studies on biodegradable magnesium implants published recently use magnesium-calcium-alloys or magnesium-aluminum-rare earth-alloys. However, since rare earths are a mixture of elements and their toxicity ...
  • Ullmann, Berit; Reifenrath, Janin; Seitz, Jan-Martin; Bormann, Dirk; Meyer-Lindenberg, Andrea (London : SAGE Publications Ltd., 2013)
    The aim of this study was to investigate the differences in the in vivo degradation behaviour of magnesium implants with various grain sizes and damaged surfaces. For this purpose, three different LAE442 magnesium implants ...
  • van Drunen, Wouter J.; Lachheb, Sarra Kacha; Glukhovskoy, Anatoly; Twiefel, Jens; Wurz, Marc C.; Lenarz, Thomas; Rau, Thomas S.; Majdani, Omid (Berlin, Boston : De Gruyter, 2017)
    For patients suffering from profound hearing loss or deafness still having respectable residual hearing in the low frequency range, the combination of a hearing aid with a cochlear implant results in the best quality of ...
  • Roth, Isabelle; Schumacher, Stephan; Basler, Tina; Baumert, Kathrin; Seitz, Jan-Marten; Evertz, Florian; Mueller, Peter Paul; Baeumer, Wolfgang; Kietzmann, Manfred (Heidelberg : Springer Heidelberg, 2015)
    Magnesium is currently under investigation as a prospective biodegradable implant material. Biodegradation of magnesium causes a release of magnesium, hydroxide ions and hydrogen gas but it can also lead to the formation ...

Search the repository


Browse

My Account

Usage Statistics