Auflistung Fakultät für Maschinenbau nach Autor/in "30df8551-4aec-4612-997c-c12b11c2e8f5"

Auflistung Fakultät für Maschinenbau nach Autor/in "30df8551-4aec-4612-997c-c12b11c2e8f5"

Sortiert nach: Sortierung: Ergebnisse:

  • Mohebbi, Saleh; Mirsalehi, Marjan; Kahrs, Lüder Alexander; Ortmaier, Tobias; Lenarz, Thomas; Majdani, Omid (Mashhad : Mashhad University of Medical Sciences, 2017)
    Introduction: Visualization of inner ear structures is a valuable strategy for researchers and clinicians working on hearing pathologies. Optical coherence tomography (OCT) is a high-resolution imaging technology which may ...
  • Mohebbi, Saleh; Lexow, Jakob; Fuchs, Alexander; Rau, Thomas; Tauscher, Sebastian; Mirsalehi, Marjan; Hosseini, Seyed Mousa Sadr; Ortmaier, Tobias; Lenarz, Thomas; Majdani, Omid (Maschhad : Mashhad University of Medical Sciences, 2018)
    Introduction: Different approaches have been developed to find the position of the internal auditory canal (IAC) in middle cranial fossa approach. A feasibility study was performed to investigate the combination of cone ...
  • Van Drunen, Wouter Johannes; Mueller, Mathias; Glukhovskoy, Anatoly; Salcher, Rolf; Wurz, Marc Christopher; Lenarz, Thomas; Maier, Hannes (New York, NY : Hindawi Publishing Corporation, 2017)
    Introduction. Most implantable hearing aids currently available were developed to compensate the sensorineural hearing loss by driving middle ear structures (e.g., the ossicles). These devices are successfully used in round ...
  • Bradel, Susanne; Doniga-Crivat, Laura; Besdo, Silke; Lexow, Franziska; Fehr, Michael; Lenarz, Thomas; Prenzler, Nils; Brandes, Gudrun (London : Hindawi, 2017)
    Conclusion. The development of a histological 3D model of the tympanic cavity visualizes the exact microanatomy of the sound conduction organ and is therefore essential for finite elements simulations and surgical training. ...
  • van Drunen, Wouter J.; Lachheb, Sarra Kacha; Glukhovskoy, Anatoly; Twiefel, Jens; Wurz, Marc C.; Lenarz, Thomas; Rau, Thomas S.; Majdani, Omid (Berlin, Boston : De Gruyter, 2017)
    For patients suffering from profound hearing loss or deafness still having respectable residual hearing in the low frequency range, the combination of a hearing aid with a cochlear implant results in the best quality of ...
  • Rau, Thomas S.; Witte, Sina; Uhlenbusch, Lea; Lexow, Jakob; Hügl, Silke; Kahrs, Lüder A.; Majdani, Omid; Lenarz, Thomas (Berlin : Walter de Gruyter, 2018)
    Hearing restoration using a cochlear implant requires a surgical access to the inner ear. In order to enhance patient safety, reduce trauma, and shorten the patient's time under anaesthesia current research focusses on ...
  • Höhl, Martin; Detemple, Daphne; Lyutenski, Stefan; Leuteritz, Georg; Varkentin, Arthur; Schmitt, Heike Andrea; Lenarz, Thomas; Roth, Bernhard; Meinhardt-Wollweber, Merve; Morgner, Uwe (Bellingham, WA : S P I E - International Society for Optical Engineering, 2017)
    Optical techniques are effective tools for diagnostic applications in medicine and are particularly attractive for the noninvasive analysis of biological tissues and fluids in vivo. Noninvasive examinations of substances ...
  • Wissel, Kirsten; Brandes, Gudrun; Pütz, Nils; Angrisani, Gian Luigi; Thieleke, Jan; Lenarz, Thomas; Durisin, Martin (San Francisco, CA : Public Library of Science, 2018)
    Despite the technological progress made with cochlear implants (CI), impedances and their diagnosis remain a focus of interest. Increases in impedance have been related to technical defects of the electrode as well as ...
  • Kilian, Julia; Blum, Tobias; Laves, Max-Heinrich; Ortmaier, Tobias; Lenarz, Thomas; Rau, Thomas S. (Berlin : De Gruyter, 2021)
    As recently demonstrated, a passive Gough-Stewart platform (a.k.a. hexapod) can be used to create a personalized surgical template to achieve minimally invasive access to the cochlea. The legs of the hexapod are manually ...
  • Schell, Viktor; Böttcher, Georg; Budde, Leon; Zuniga, M. Geraldine; Lenarz, Thomas; Rau, Thomas (Berlin : De Gruyter, 2021)
    The electrode array insertion is a critical point during CI surgery and should be performed as gently as possible to preserve residual hearing. In order to measure occurring forces, an insertion tool with an integrated ...
  • Cramer, Jakob; Dassow, Niklas; Böttcher-Rebmann, Georg; Budde, Leon; Lenarz, Thomas; Rau, Thomas S. (Berlin : De Gruyter, 2023)
    In research on cochlear implants, preclinical testing of newly developed electrode arrays and surgical tools is an essential procedure, which requires the availability of a suitable testing environment. For this purpose, ...
  • Granna, Josephine; Rau, Thomas S.; Nguyen, Thien-Dang; Lenarz, Thomas; Majdani, Omid; Burgner-Kahrs, Jessica (Bellingham, Wash. : SPIE, 2016)
    During manual cochlear implant electrode insertion the surgeon is at risk to damage the intracochlear fine-structure, as the electrode array is inserted through a small opening in the cochlea blindly with little force-feedback. ...

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken