Correction: Mechanical properties of femoral trabecular bone in dogs

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/4987
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/5031
dc.contributor.author Pressel, Thomas
dc.contributor.author Bouguecha, Anas
dc.contributor.author Vogt, Ute
dc.contributor.author Meyer-Lindenberg, Andrea
dc.contributor.author Behrens, Bernd-Arno
dc.contributor.author Nolte, Ingo
dc.contributor.author Windhagen, Henning
dc.date.accessioned 2019-06-26T06:32:25Z
dc.date.available 2019-06-26T06:32:25Z
dc.date.issued 2005
dc.identifier.citation Pressel, Thomas; Bouguecha, Anas; Vogt, Ute; Meyer-Lindenberg, Andrea; Behrens, Bernd-Arno et al.: Correction: Mechanical properties of femoral trabecular bone in dogs. In: Biomedical Engineering Online 4 (2005), Nr. 1, 66. DOI: https://doi.org/10.1186/1475-925x-4-66
dc.description.abstract After the publication of this work [1], we became aware of the fact that the frequency of the ultrasound transmitter that we used for determining the elastic moduli of the trabecular bone specimens was not correctly specified. The oscillation frequency of the ultrasound transmitter was 2 MHz (and not 100 MHz as stated in our work) while we used a sampling rate of 100 MHz. In our publication, the oscillation frequency and sampling rate were confounded. Therefore also the statement in the discussion that we might have determined elastic moduli of trabecular bone tissue rather than the elastic properties of whole specimens because we used an ultrasound frequency > 2 MHz is wrong and has to be omitted. eng
dc.language.iso eng
dc.publisher London : BioMed Central Ltd.
dc.relation.ispartofseries Biomedical Engineering Online 4 (2005), Nr. 1
dc.rights CC BY 2.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/2.0/
dc.subject Biomedical engineering eng
dc.subject Sampling (signal processing) eng
dc.subject Ultrasound eng
dc.subject Trabecular bone tissue eng
dc.subject Computer science eng
dc.subject Elastic modulus eng
dc.subject Transmitter eng
dc.subject.ddc 610 | Medizin, Gesundheit ger
dc.subject.ddc 600 | Technik ger
dc.title Correction: Mechanical properties of femoral trabecular bone in dogs eng
dc.type Article
dc.type Text
dc.relation.issn 1475-925X
dc.relation.doi https://doi.org/10.1186/1475-925x-4-66
dc.bibliographicCitation.issue 1
dc.bibliographicCitation.volume 4
dc.bibliographicCitation.firstPage 66
dc.description.version publishedVersion