Real-Time Gait Analysis Using a Single Head-Worn Inertial Measurement Unit

Show simple item record

dc.identifier.uri http://dx.doi.org/10.15488/4952
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/4996
dc.contributor.author Hwang, Tong-Hun ger
dc.contributor.author Reh, Julia ger
dc.contributor.author Effenberg, Alfred O. ger
dc.contributor.author Blume, Holger ger
dc.date.accessioned 2019-06-06T11:26:18Z
dc.date.available 2019-06-06T11:26:18Z
dc.date.issued 2018
dc.identifier.citation Hwang, T.-H.; Reh, J.; Effenberg, A.O.; Blume, H.: Real-Time Gait Analysis Using a Single Head-Worn Inertial Measurement Unit. In: IEEE Transactions on Consumer Electronics 64 (2018), Nr. 2, S. 240-248. DOI: https://doi.org/10.1109/TCE.2018.2843289 ger
dc.description.abstract The background of this paper is to apply advanced real-time gait analysis to walking interventions in daily life setting. A vast of wearable devices provide gait information but not more than pedometer functions such as step counting, displacement, and velocity. This paper suggests a real-time gait analysis method based on a head-worn inertial measurement unit. A novel analysis method implements real-time detection of gait events (heel strike, toe off, and mid-stance phase) and immediately provides detailed spatiotemporal parameters. The reliability of this method was proven by a measurement with over 11 000 steps from seven participants on a 400-m outdoor track. The advanced gait analysis was conducted without any limitation of a fixed reference frame (e.g., indoor stage and infrared cameras). The mean absolute error in step-counting was 0.24%. Compared to a pedometer, additional gait parameters were obtained such as foot-ground contact time (CT) and CT ratio. The gait monitoring system can be used as real-time and long-term feedback, which is applicable in the management of the health status and on injury prevention. © 2018 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. ger
dc.description.sponsorship European Commission/H2020-FETPROACT-2014/641321/EU ger
dc.language.iso eng ger
dc.publisher Piscataway, NJ : IEEE
dc.relation info:eu-repo/grantAgreement/European Commission/H2020-FETPROACT-2014/641321/EU ger
dc.relation.ispartofseries IEEE Transactions on Consumer Electronics 64 (2018), Nr. 2 ger
dc.rights Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. ger
dc.subject Biomedical monitoring eng
dc.subject Gait analysis eng
dc.subject Inertial measurement unit eng
dc.subject Smart devices eng
dc.subject Wearable sensors eng
dc.subject.ddc 610 | Medizin, Gesundheit ger
dc.subject.ddc 790 | Freizeitgestaltung, Darstellende Kunst ger
dc.title Real-Time Gait Analysis Using a Single Head-Worn Inertial Measurement Unit eng
dc.type Article ger
dc.type Text ger
dc.relation.doi 10.1109/TCE.2018.2843289
dc.bibliographicCitation.firstPage 240
dc.bibliographicCitation.lastPage 248
dc.description.version acceptedVersion ger
tib.accessRights frei zug�nglich ger


Files in this item

This item appears in the following Collection(s):

Show simple item record

 

Search the repository


Browse

My Account

Usage Statistics