Ion mobility spectrometer with orthogonal X-Ray source for increased sensitivity

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/4410
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/4450
dc.contributor.author Bunert, Erik ger
dc.contributor.author Reinecke, Tobias ger
dc.contributor.author Kirk, Ansgar T. ger
dc.contributor.author Bohnhorst, Alexander ger
dc.contributor.author Zimmermann, Stefan ger
dc.date.accessioned 2019-01-25T10:01:16Z
dc.date.available 2020-08-01T22:05:02Z
dc.date.issued 2018
dc.identifier.citation Bunert, E.; Reinecke, T.; Kirk, A.T.; Bohnhorst, A.; Zimmermann, S.: Ion mobility spectrometer with orthogonal X-Ray source for increased sensitivity. In: Talanta 185 (2018), S. 537-541. DOI: https://doi.org/10.1016/j.talanta.2018.04.035 ger
dc.description.abstract Ion mobility spectrometers (IMS) are compact devices for extremely sensitive detection of proton and electron affine volatile compounds down to low pptv concentrations within less than a second. The measuring principle requires ionization of the target analyte. Most IMS employ radioactive electron sources, such as 63Ni or 3H. These radioactive materials suffer from legal restrictions limiting the fields of application. Furthermore, the electron emission has a predetermined intensity and cannot be controlled or disabled. In a previous work, we replaced the axially mounted 3H source of our ion mobility spectrometer with a commercially available X-ray source operated at low acceleration voltage of 4.5 kV to be applicable in most application without legal restrictions. However, the high penetration depth of the radiation together with the statistical behavior of the X-ray ionization process led to an increase of Fano noise and thus a limited signal-to-noise ratio. Therefore, the X-ray source is now mounted orthogonal to the drift tube in order to avoid Fano noise. Here, we compare the analytical performance of this orthogonal setup with the axially mounted X-ray source. The noise level is significantly reduced. This improves the signal-to-noise ratio from 700 with the axially placed source to more than 3000 with the orthogonally placed source, while the resolving power still remains at R = 100. Furthermore, typical limits of detection for some model substances in the low pptv range in positive and negative ion mode are given. ger
dc.language.iso eng ger
dc.publisher Amsterdam : Elsevier
dc.relation.ispartofseries Talanta 185 (2018) ger
dc.rights CC BY-NC-ND 3.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/3.0/
dc.subject Ion Mobility Spectrometry eng
dc.subject X-ray IMS eng
dc.subject Orthogonal X-ray source eng
dc.subject X-ray ionization eng
dc.subject Non-radioactive ionization source eng
dc.subject.ddc 621,3 | Elektrotechnik, Elektronik ger
dc.title Ion mobility spectrometer with orthogonal X-Ray source for increased sensitivity eng
dc.type Article ger
dc.type Text ger
dc.relation.doi 10.1016/j.talanta.2018.04.035
dc.bibliographicCitation.firstPage 537
dc.bibliographicCitation.lastPage 541
dc.description.version acceptedVersion ger
tib.accessRights frei zug�nglich