Towards microprocessor-based control of droplet parameters for endoscopic laryngeal adductor reflex triggering

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/4022
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/4056
dc.contributor.author Friedemann Fast, Jacob ger
dc.contributor.author Muley, Apurva ger
dc.contributor.author Kühn, Daniela ger
dc.contributor.author Meisoll, Frederik ger
dc.contributor.author Ortmaier, Tobias ger
dc.contributor.author Jungheim, Michael ger
dc.contributor.author Ptok, Martin ger
dc.date.accessioned 2018-11-22T14:03:15Z
dc.date.available 2018-11-22T14:03:15Z
dc.date.issued 2017
dc.identifier.citation Friedemann Fast, J. et al.: Towards microprocessor-based control of droplet parameters for endoscopic laryngeal adductor reflex triggering. In: Current Directions in Biomedical Engineering 3 (2017), S. 239-243. DOI: https://doi.org/10.1515/cdbme-2017-0050 ger
dc.description.abstract The so-called Laryngeal Adductor Reflex (LAR) protects the respiratory tract from particle intrusion by quickly approximating the vocal folds to close the free glottal space. An impaired LAR may be associated with an increased risk of aspiration and other adverse conditions. To evaluate the integrity of the LAR, we recently developed an endoscopic prototype for LAR triggering by shooting accelerated droplets onto a predefined laryngeal target region. We now modified the existing droplet-dispensing system to adapt the fluid system pressure as well as the valve opening time to user-chosen values autonomously. This has been accomplished using a microcontroller board connected to a pressure sensor and a mechatronic syringe pump. For performance validation, we designed a measurement setup capable of tracking the droplet along a vertical trajectory. In addition to the experimental setup, the influence of parameters such as system pressure and valve opening time on the micro-droplet formation is presented. Further development will enable the physician to adjust the droplet momentum by setting a single input value on the microcontroller-based setup, thus further increasing usability of the diagnostic device. ger
dc.language.iso eng ger
dc.publisher Berlin, Boston : De Gruyter
dc.relation.ispartofseries Current Directions in Biomedical Engineering 3 (2017) ger
dc.rights CC BY-NC-ND 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject dysphagia eng
dc.subject aspiration pneumonia eng
dc.subject larynx eng
dc.subject vocal folds eng
dc.subject Laryngeal Adductor Reflex (LAR) eng
dc.subject droplet-dispensing system eng
dc.subject solenoid valve eng
dc.subject.ddc 600 | Technik ger
dc.subject.ddc 610 | Medizin, Gesundheit ger
dc.title Towards microprocessor-based control of droplet parameters for endoscopic laryngeal adductor reflex triggering eng
dc.type Article ger
dc.type Text ger
dc.relation.essn 2364-5504
dc.relation.doi 10.1515/cdbme-2017-0050
dc.bibliographicCitation.firstPage 239
dc.bibliographicCitation.lastPage 243
dc.description.version publishedVersion ger
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken