Investigation of intracochlear dual actuator stimulation in a scaled test rig

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/4016
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/4050
dc.contributor.author van Drunen, Wouter J. ger
dc.contributor.author Lachheb, Sarra Kacha ger
dc.contributor.author Glukhovskoy, Anatoly ger
dc.contributor.author Twiefel, Jens ger
dc.contributor.author Wurz, Marc C. ger
dc.contributor.author Lenarz, Thomas ger
dc.contributor.author Rau, Thomas S. ger
dc.contributor.author Majdani, Omid ger
dc.date.accessioned 2018-11-22T12:41:53Z
dc.date.available 2018-11-22T12:41:53Z
dc.date.issued 2017
dc.identifier.citation van Drunen, W.J. et al.: Investigation of intracochlear dual actuator stimulation in a scaled test rig. In: Current Directions in Biomedical Engineering 3 (2017), S. 119-122. DOI: https://doi.org/10.1515/cdbme-2017-0024 ger
dc.description.abstract For patients suffering from profound hearing loss or deafness still having respectable residual hearing in the low frequency range, the combination of a hearing aid with a cochlear implant results in the best quality of hearing perception (EAS – electric acoustic stimulation). In order to optimize EAS, ongoing research focusses on the integration of these stimuli in a single implant device. Within this study, the performance of piezoelectric actuators, particularly the dual actuator stimulation, in a scaled uncoiled test rig was investigated. ger
dc.language.iso eng ger
dc.publisher Berlin, Boston : De Gruyter
dc.relation.ispartofseries Current Directions in Biomedical Engineering 3 (2017) ger
dc.rights CC BY-NC-ND 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject Cochlea eng
dc.subject EAS eng
dc.subject EMS eng
dc.subject intracochlear stimulation eng
dc.subject cochlear implant eng
dc.subject piezoelectric bending actuator eng
dc.subject basilar membrane model eng
dc.subject.ddc 600 | Technik ger
dc.subject.ddc 610 | Medizin, Gesundheit ger
dc.title Investigation of intracochlear dual actuator stimulation in a scaled test rig eng
dc.type Article ger
dc.type Text ger
dc.relation.essn 2364-5504
dc.relation.doi 10.1515/cdbme-2017-0024
dc.bibliographicCitation.firstPage 119
dc.bibliographicCitation.lastPage 122
dc.description.version publishedVersion ger
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken