dc.identifier.uri |
http://dx.doi.org/10.15488/4016 |
|
dc.identifier.uri |
https://www.repo.uni-hannover.de/handle/123456789/4050 |
|
dc.contributor.author |
van Drunen, Wouter J.
|
ger |
dc.contributor.author |
Lachheb, Sarra Kacha
|
ger |
dc.contributor.author |
Glukhovskoy, Anatoly
|
ger |
dc.contributor.author |
Twiefel, Jens
|
ger |
dc.contributor.author |
Wurz, Marc C.
|
ger |
dc.contributor.author |
Lenarz, Thomas
|
ger |
dc.contributor.author |
Rau, Thomas S.
|
ger |
dc.contributor.author |
Majdani, Omid
|
ger |
dc.date.accessioned |
2018-11-22T12:41:53Z |
|
dc.date.available |
2018-11-22T12:41:53Z |
|
dc.date.issued |
2017 |
|
dc.identifier.citation |
van Drunen, W.J. et al.: Investigation of intracochlear dual actuator stimulation in a scaled test rig. In: Current Directions in Biomedical Engineering 3 (2017), S. 119-122. DOI: https://doi.org/10.1515/cdbme-2017-0024 |
ger |
dc.description.abstract |
For patients suffering from profound hearing loss or deafness still having respectable residual hearing in the low frequency range, the combination of a hearing aid with a cochlear implant results in the best quality of hearing perception (EAS – electric acoustic stimulation). In order to optimize EAS, ongoing research focusses on the integration of these stimuli in a single implant device. Within this study, the performance of piezoelectric actuators, particularly the dual actuator stimulation, in a scaled uncoiled test rig was investigated. |
ger |
dc.language.iso |
eng |
ger |
dc.publisher |
Berlin, Boston : De Gruyter |
|
dc.relation.ispartofseries |
Current Directions in Biomedical Engineering 3 (2017) |
ger |
dc.rights |
CC BY-NC-ND 4.0 Unported |
|
dc.rights.uri |
https://creativecommons.org/licenses/by-nc-nd/4.0/ |
|
dc.subject |
Cochlea |
eng |
dc.subject |
EAS |
eng |
dc.subject |
EMS |
eng |
dc.subject |
intracochlear stimulation |
eng |
dc.subject |
cochlear implant |
eng |
dc.subject |
piezoelectric bending actuator |
eng |
dc.subject |
basilar membrane model |
eng |
dc.subject.ddc |
600 | Technik
|
ger |
dc.subject.ddc |
610 | Medizin, Gesundheit
|
ger |
dc.title |
Investigation of intracochlear dual actuator stimulation in a scaled test rig |
eng |
dc.type |
Article |
ger |
dc.type |
Text |
ger |
dc.relation.essn |
2364-5504 |
|
dc.relation.doi |
10.1515/cdbme-2017-0024 |
|
dc.bibliographicCitation.firstPage |
119 |
|
dc.bibliographicCitation.lastPage |
122 |
|
dc.description.version |
publishedVersion |
ger |
tib.accessRights |
frei zug�nglich |
|