Flow Measurements in Two Cambered Vane Diffusers with Different Passage Widths

Show simple item record

dc.identifier.uri http://dx.doi.org/10.15488/3606
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/3638
dc.contributor.author Stein, W.
dc.contributor.author Rautenberg, M.
dc.date.accessioned 2018-08-23T12:15:42Z
dc.date.available 2018-08-23T12:15:42Z
dc.date.issued 1987
dc.identifier.citation Stein, W.; Rautenberg, M.: Flow Measurements in Two Cambered Vane Diffusers with Different Passage Widths. In: International Journal of Turbo and Jet Engines 4 (1987), S. 131-138. DOI: https://doi.org/10.1515/TJJ.1987.4.1-2.131
dc.description.abstract To investigate the influence of the vaneless space between impeller exit and the diffuser vanes, detailed flow measurements in two diffusers with the same vane geometry but different passage width are compared. The three—dimensional character of the flow changes between impeller exit and the entry to the two dimensional vanes depending on the shape of the shroud. After initial measurements with a constant area vaneless space, the width of the vaned diffuser was later on reduced by 10%. The compressor maps show an increase in overall pressure rise and efficiency with the width reduction. To get further details of the flow field, measurements of the static pressure distribution at hub and shroud have been performed at several operation points for both diffusers. At the same points the flow angle and total pressure distribution between hub and shroud upstream and downstream of the vanes have been measured with probes. The maximum efficiency of the narrow diffuser is nearly 2% higher than for the wide diffuser. The measurements give further details to explain these improvements. © Freund Publishing House Ltd. eng
dc.language.iso eng
dc.publisher Berlin : De Gruyter
dc.relation.ispartofseries International Journal of Turbo and Jet Engines 4 (1987)
dc.rights Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. Dieser Beitrag ist aufgrund einer (DFG-geförderten) Allianz- bzw. Nationallizenz frei zugänglich.
dc.subject Flow Measurement eng
dc.subject Diffuser eng
dc.subject Vane eng
dc.subject.ddc 620 | Ingenieurwissenschaften und Maschinenbau ger
dc.title Flow Measurements in Two Cambered Vane Diffusers with Different Passage Widths
dc.type Article
dc.type Text
dc.relation.issn 03340082
dc.relation.doi https://doi.org/10.1515/TJJ.1987.4.1-2.131
dc.bibliographicCitation.volume 4
dc.bibliographicCitation.firstPage 131
dc.bibliographicCitation.lastPage 138
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Files in this item

This item appears in the following Collection(s):

Show simple item record

 

Search the repository


Browse

My Account

Usage Statistics