Influence of AFP Process Parameters on the Temperature Distribution Used for Thermal in-process Monitoring

Show simple item record

dc.identifier.uri http://dx.doi.org/10.15488/1828
dc.identifier.uri http://www.repo.uni-hannover.de/handle/123456789/1853
dc.contributor.author Schmidt, C.
dc.contributor.author Denkena, Berend
dc.contributor.author Hocke, T.
dc.contributor.author Völtzer, K.
dc.date.accessioned 2017-09-07T11:22:18Z
dc.date.available 2017-09-07T11:22:18Z
dc.date.issued 2017
dc.identifier.citation Schmidt, C.; Denkena, B.; Hocke, T.; Völtzer, K.: Influence of AFP Process Parameters on the Temperature Distribution Used for Thermal in-process Monitoring. In: Procedia CIRP 66 (2017), S. 68-73. DOI: https://doi.org/10.1016/j.procir.2017.03.220
dc.description.abstract Automated Fiber Placement is an important manufacturing process when it comes to aerospace part generation. To minimize the machine downtime, an online monitoring system is necessary to prevent time consuming visual inspection. Therefore, a new thermal in-process monitoring system is integrated. Herewith spotted temperature difference enable the localization of placed tows and detection of defects. The thermal contrast between subsurface and tows depends on different process parameters such as lay-up speed, tooling temperature and compaction pressure. This influence is analyzed and discussed within lay-up studies to gain further knowledge about the different effects to increase the reliability of in-process monitoring as well as AFP processes. eng
dc.description.sponsorship Therm-O-Plan
dc.description.sponsorship Niedersächsisches Vorab, Volkswagen Foundation
dc.language.iso eng
dc.publisher Amsterdam : Elsevier
dc.relation.ispartofseries Procedia CIRP 66 (2017)
dc.rights CC BY-NC-ND 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject Automated Fiber Placement eng
dc.subject Process Monitoring eng
dc.subject Thermography eng
dc.subject Composite materials eng
dc.subject Manufacture eng
dc.subject Process control eng
dc.subject Process monitoring eng
dc.subject Thermography (temperature measurement) eng
dc.subject Compaction pressure eng
dc.subject Detection of defects eng
dc.subject Fiber placement eng
dc.subject In-process monitoring eng
dc.subject Manufacturing process eng
dc.subject On-line monitoring system eng
dc.subject Process parameters eng
dc.subject Temperature differences eng
dc.subject Monitoring eng
dc.subject.ddc 620 | Ingenieurwissenschaften und Maschinenbau ger
dc.title Influence of AFP Process Parameters on the Temperature Distribution Used for Thermal in-process Monitoring eng
dc.type Article
dc.type Text
dc.relation.issn 00136848
dc.relation.doi https://doi.org/10.1016/j.procir.2017.03.220
dc.bibliographicCitation.volume 66
dc.bibliographicCitation.firstPage 68
dc.bibliographicCitation.lastPage 73