Radiation pressure calibration and test mass reflectivities for LISA Pathfinder

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/1731
dc.identifier.uri http://www.repo.uni-hannover.de/handle/123456789/1756
dc.contributor.author Korsakova, N.
dc.contributor.author Kaune, B.
dc.date.accessioned 2017-07-17T11:09:07Z
dc.date.available 2017-07-17T11:09:07Z
dc.date.issued 2017
dc.identifier.citation Korsakova, N.; Kaune, B.: Radiation pressure calibration and test mass reflectivities for LISA Pathfinder. In: Journal of Physics: Conference Series 840 (2017), Nr. 1, 12039. DOI: https://doi.org/10.1088/1742-6596/840/1/012039
dc.description.abstract This paper describes a series of experiments which were carried out during the main operations of LISA Pathfinder. These experiments were performed by modulating the power of the measurement and reference beams. In one series of experiments the beams were sequentially switched on and off. In the other series of experiments the powers of the beams were modulated within 0.1% and 1% of the constant power. These experiments use recordings of the total power measured on the photodiodes to infer the properties of the Optical Metrology System (OMS), such as reflectivities of the test masses and change of the photodiode efficiencies with time. In the first case the powers are back propagated from the different photodiodes to the same place on the optical bench to express the unknown quantities in the measurement with the complimentary photodiode measurements. They are combined in the way that the only unknown left is the test mass reflectivities. The second experiment compared two estimates of the force applied to the test masses due to the radiation pressure that appears because of the beam modulations. One estimate of the force is inferred from the measurements of the powers on the photodiodes and propagation of this measurement to the test masses. The other estimation of the force is done by calculating it from the change in the main scientific output of the instrument - differential displacement of the two test masses. © Published under licence by IOP Publishing Ltd. eng
dc.description.sponsorship DLR
dc.description.sponsorship Federal Ministry for Economic Affairs and Energy
dc.description.sponsorship Royal Society
dc.description.sponsorship Scottish University Physics Alliance (SUPA)
dc.language.iso eng
dc.publisher Bristol : Institute of Physics Publishing
dc.relation.ispartofseries Journal of Physics: Conference Series 840 (2017), Nr. 1
dc.rights CC BY 3.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/3.0/
dc.subject Pressure eng
dc.subject Reflection eng
dc.subject Space probes eng
dc.subject Beam modulation eng
dc.subject Differential displacements eng
dc.subject LISA Pathfinder eng
dc.subject Optical Metrology eng
dc.subject Radiation pressure eng
dc.subject Reference beams eng
dc.subject Scientific output eng
dc.subject Unknown quantity eng
dc.subject Photodiodes eng
dc.subject.classification Konferenzschrift ger
dc.subject.ddc 530 | Physik ger
dc.title Radiation pressure calibration and test mass reflectivities for LISA Pathfinder
dc.type Article
dc.type Text
dc.relation.issn 1742-6588
dc.relation.doi https://doi.org/10.1088/1742-6596/840/1/012039
dc.bibliographicCitation.issue 1
dc.bibliographicCitation.volume 840
dc.bibliographicCitation.firstPage 12039
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken