The use of power lines as a communication channel for transferring data between communication devices for power systems in smart grid communication systems is growing rapidly. This paper describes three different types of methods for radiating and conducting Intentional Electromagnetic Interference, IEMI, signals: Amplitude Modulated, Damped Sinusoidal and Sweep Frequency Jamming Signals. The severity of all three types of IEMI signals on a power line communication channel using a single phase of a three-phase, low-voltage power distribution board is compared. The method for measuring interference is then explained and the influence of radiated and conducted interferences on data transmission is assessed. After discussing the IEEE 1901 power line communication channel's vulnerability to IEMI, this article explains the need for a systematic risk-based approach, in coalition with the rules-based perspective, to mitigate its impact.© 2021 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.
|