dc.identifier.uri |
http://dx.doi.org/10.15488/1487 |
|
dc.identifier.uri |
http://www.repo.uni-hannover.de/handle/123456789/1512 |
|
dc.contributor.author |
Herlemann, H.
|
|
dc.contributor.author |
Koch, M.
|
|
dc.date.accessioned |
2017-05-10T12:50:20Z |
|
dc.date.available |
2017-05-10T12:50:20Z |
|
dc.date.issued |
2008 |
|
dc.identifier.citation |
Herlemann, H.; Koch, M.: Measurement of the transient shielding effectiveness of shielding cabinets. In: Advances in Radio Science 6 (2008), S. 293-298. DOI: https://doi.org/10.5194/ars-6-293-2008 |
|
dc.description.abstract |
Recently, new definitions of shielding effectiveness (SE) for high-frequency and transient electromagnetic fields were introduced by Klinkenbusch (2005). Analytical results were shown for closed as well as for non closed cylindrical shields. In the present work, the shielding performance of different shielding cabinets is investigated by means of numerical simulations and measurements inside a fully anechoic chamber and a GTEM-cell. For the GTEM-cell-measurements, a downscaled model of the shielding cabinet is used. For the simulations, the numerical tools CONCEPT II and COMSOL MULTIPHYSICS were available. The numerical results agree well with the measurements. They can be used to interpret the behaviour of the shielding effectiveness of enclosures as function of frequency. From the measurement of the electric and magnetic fields with and without the enclosure in place, the electric and magnetic shielding effectiveness as well as the transient shielding effectiveness of the enclosure are calculated. The transient SE of four different shielding cabinets is determined and discussed. © Author(s) 2008. |
eng |
dc.language.iso |
eng |
|
dc.publisher |
Göttingen : Copernicus GmbH |
|
dc.relation.ispartofseries |
Advances in Radio Science 6 (2008) |
|
dc.rights |
CC BY 3.0 Unported |
|
dc.rights.uri |
https://creativecommons.org/licenses/by/3.0/ |
|
dc.subject |
Comsol multiphysics |
eng |
dc.subject |
Electric and magnetic fields |
eng |
dc.subject |
Function of frequency |
eng |
dc.subject |
Magnetic shielding effectiveness |
eng |
dc.subject |
Shielding effectiveness |
eng |
dc.subject |
Shielding performance |
eng |
dc.subject |
Simulations and measurements |
eng |
dc.subject |
Transient electromagnetic fields |
eng |
dc.subject |
Enclosures |
eng |
dc.subject |
Magnetic shielding |
eng |
dc.subject.ddc |
621,3 | Elektrotechnik, Elektronik
|
ger |
dc.title |
Measurement of the transient shielding effectiveness of shielding cabinets |
|
dc.type |
Article |
|
dc.type |
Text |
|
dc.relation.issn |
1684-9965 |
|
dc.relation.doi |
https://doi.org/10.5194/ars-6-293-2008 |
|
dc.bibliographicCitation.volume |
6 |
|
dc.bibliographicCitation.firstPage |
293 |
|
dc.bibliographicCitation.lastPage |
298 |
|
dc.description.version |
publishedVersion |
|
tib.accessRights |
frei zug�nglich |
|