Field calibration for multidirectional spectroradiometers

Zur Kurzanzeige

dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/14797
dc.identifier.uri https://doi.org/10.15488/14679
dc.contributor.author Niedzwiedz, Angelika
dc.contributor.author Duffert, Jens
dc.contributor.author Tobar-Foster, Mario
dc.contributor.author Heinzel, Jan Wilko
dc.contributor.author Seckmeyer, Gunther
dc.date.accessioned 2023-09-01T06:38:32Z
dc.date.available 2023-09-01T06:38:32Z
dc.date.issued 2022
dc.identifier.citation Niedzwiedz, A.; Duffert, J.; Tobar-Foster, M.; Heinzel, J.W.; Seckmeyer, G.: Field calibration for multidirectional spectroradiometers. In: Measurement Science and Technology 33 (2022), Nr. 6, 065904. DOI: https://doi.org/10.1088/1361-6501/ac56be
dc.description.abstract A mobile calibration system for a multidirectional spectroradiometer (MUDIS) to transfer the absolute radiometric calibration from the laboratory to the location of the outdoor-measurement (field calibrator) has been developed. The main part of the calibration system comprises an aluminium sphere with a diameter of 40 cm, mounting adapters and a ventilation system. The MUDIS device is capable of measuring spectral radiance from 320 to 600 nm in 113 different directions simultaneously within 1 s. When repeating radiance measurements inside the mobile field sphere, the relative standard deviation (RSD) for wavelengths between 320 and 600 nm is less than 1.8% (320 nm) for all directions with minimum RSD of 0.6% at 382 nm. The reproducibility depends not only on the wavelength but also on the individual fibre position on the hemispherical input optics, with maximum of 4.5% RSD, but most directions show a lower deviation. On average, the RSD for the channels is less than 0.9%. The calibrator enables measurements of the spectral radiance with less uncertainty than with the previous indirect calibration method, which uses measurements of a scanning reference array spectroradiometer. eng
dc.language.iso eng
dc.publisher Bristol : IOP Publ. Ltd.
dc.relation.ispartofseries Measurement Science and Technology 33 (2022), Nr. 6
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0
dc.subject field calibration eng
dc.subject multidirectional eng
dc.subject multidirectional spectroradiometer (MUDIS) eng
dc.subject reproducibility eng
dc.subject spectral radiance eng
dc.subject.ddc 600 | Technik
dc.subject.ddc 620 | Ingenieurwissenschaften und Maschinenbau
dc.title Field calibration for multidirectional spectroradiometers eng
dc.type Article
dc.type Text
dc.relation.essn 1361-6501
dc.relation.issn 0957-0233
dc.relation.doi https://doi.org/10.1088/1361-6501/ac56be
dc.bibliographicCitation.issue 6
dc.bibliographicCitation.volume 33
dc.bibliographicCitation.firstPage 065904
dc.description.version publishedVersion eng
tib.accessRights frei zug�nglich
dc.bibliographicCitation.articleNumber 065904