Biomechanical comparison of a new expandable intramedullary nail and conventional intramedullary nails for femoral osteosynthesis in dogs

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/10843
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/10921
dc.contributor.author Plenert, T.
dc.contributor.author Garlichs, G.
dc.contributor.author Nolte, I.
dc.contributor.author Harder, L.
dc.contributor.author Hootak, M.
dc.contributor.author Kramer, S.
dc.contributor.author Behrens, B.-A.
dc.contributor.author Bach, J.-P.
dc.date.accessioned 2021-04-30T05:23:11Z
dc.date.available 2021-04-30T05:23:11Z
dc.date.issued 2020
dc.identifier.citation Plenert, T.; Garlichs, G.; Nolte, I.; Harder, L.; Hootak, M. et al.: Biomechanical comparison of a new expandable intramedullary nail and conventional intramedullary nails for femoral osteosynthesis in dogs. In: PLoS ONE 15 (2020), Nr. 5, e0231823. DOI: https://doi.org/10.1371/journal.pone.0231823
dc.description.abstract Intramedullary nailing of diaphyseal femoral fractures is a commonly used treatment method in dogs because of its biological and biomechanical advantages compared to bone plating. To achieve adequate resistance of the intramedullary nail against torsional and axial compressive forces, additional application of transcortical screws is needed. As these interlocking screws represent a frequent cause of post-operative complications, a new expandable intramedullary nail (EXPN) was developed, which was designed to provide adequate fracture stabilisation without the need for transcortical fixation. The evaluation of the biomechanical properties of the new EXPN with regard to torsional, compressive and bending stability as well as direct comparison to the biomechanical properties of conventional Steinmann (STMN)- and interlocking (ILN) nails was carried out with different biomechanical test arrangements. No significant statistical differences regarding the torsional and bending resistance between the EXPN and ILN group were seen, which indicates that rotatory as well as bending stability of the innovative EXPN is similar to the conventional ILN. Nevertheless, the percentage deviation between the attempted and successfully reached physiological compressive forces was significantly higher (p = 0.045) in the EXPN group compared to the ILN group, which indicates that the compressive stability of the innovative EXPN might be weaker compared to the ILN. In summary, the new EXPN represents an interesting alternative to conventional intramedullary nails. However, in direct comparison to conventional interlocking nails, the EXPN has shown weaknesses in the neutralization of axial compressive forces, which indicates that at least biomechanically the interlocking nail seems advantageous. Further in-vitro and in-vivo investigations are required before clinical use can be recommended. © 2020 Plenert et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. eng
dc.language.iso eng
dc.publisher San Francisco, California, US : PLOS
dc.relation.ispartofseries PLoS ONE 15 (2020), Nr. 5
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0/
dc.subject bone plating eng
dc.subject expandable intramedullary nail (EXPN) eng
dc.subject conventional Steinmann (STMN) eng
dc.subject interlocking (ILN) nails eng
dc.subject.ddc 500 | Naturwissenschaften ger
dc.subject.ddc 610 | Medizin, Gesundheit ger
dc.title Biomechanical comparison of a new expandable intramedullary nail and conventional intramedullary nails for femoral osteosynthesis in dogs
dc.type Article
dc.type Text
dc.relation.essn 1932-6203
dc.relation.doi https://doi.org/10.1371/journal.pone.0231823
dc.bibliographicCitation.issue 5
dc.bibliographicCitation.volume 15
dc.bibliographicCitation.firstPage e0231823
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken