Electrospray sample injection for single-particle imaging with x-ray lasers

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/10470
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/10546
dc.contributor.author Bielecki, Johan
dc.contributor.author Hantke, Max F.
dc.contributor.author Daurer, Benedikt J.
dc.contributor.author Reddy, Hemanth K.N.
dc.contributor.author Hasse, Dirk
dc.contributor.author Larsson, Daniel S.D.
dc.contributor.author Gunn, Laura H.
dc.contributor.author Svenda, Martin
dc.contributor.author Iwan, Bianca
dc.date.accessioned 2021-03-02T10:17:48Z
dc.date.available 2021-03-02T10:17:48Z
dc.date.issued 2019
dc.identifier.citation Bielecki, J.; Hantke, M.F.; Daurer, B.J. et al.: Electrospray sample injection for single-particle imaging with x-ray lasers. In: Science Advances 5 (2019), Nr. 5, eaav8801. DOI: https://doi.org/10.1126/sciadv.aav8801
dc.description.abstract The possibility of imaging single proteins constitutes an exciting challenge for x-ray lasers. Despite encouraging results on large particles, imaging small particles has proven to be difficult for two reasons: not quite high enough pulse intensity from currently available x-ray lasers and, as we demonstrate here, contamination of the aerosolized molecules by nonvolatile contaminants in the solution. The amount of contamination on the sample depends on the initial droplet size during aerosolization. Here, we show that, with our electrospray injector, we can decrease the size of aerosol droplets and demonstrate virtually contaminant-free sample delivery of organelles, small virions, and proteins. The results presented here, together with the increased performance of next-generation x-ray lasers, constitute an important stepping stone toward the ultimate goal of protein structure determination from imaging at room temperature and high temporal resolution. © 2019 The Authors. eng
dc.language.iso eng
dc.publisher Washington : American Association for the Advancement of Science (A A A S)
dc.relation.ispartofseries Science Advances 5 (2019), Nr. 5
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0/
dc.subject Aerosols eng
dc.subject Contamination eng
dc.subject Drops eng
dc.subject Proteins eng
dc.subject X rays eng
dc.subject Aerosolization eng
dc.subject High temporal resolution eng
dc.subject Large particles eng
dc.subject Protein structures eng
dc.subject Pulse intensity eng
dc.subject Sample injection eng
dc.subject Single particle eng
dc.subject Small particles eng
dc.subject X ray lasers eng
dc.subject.ddc 500 | Naturwissenschaften ger
dc.title Electrospray sample injection for single-particle imaging with x-ray lasers
dc.type Article
dc.type Text
dc.relation.essn 2375-2548
dc.relation.doi https://doi.org/10.1126/sciadv.aav8801
dc.bibliographicCitation.issue 5
dc.bibliographicCitation.volume 5
dc.bibliographicCitation.firstPage eaav8801
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 