Innovative 3D Model of the Human Middle Ear in High Resolution with a Histological Microgrinding Method: A Feasibility Study and Comparison with μCT

Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Bradel, S. et al.: Innovative 3D Model of the Human Middle Ear in High Resolution with a Histological Microgrinding Method: A Feasibility Study and Comparison with μCT. In: International Journal of Otolaryngology (2017), 6753604. DOI: https://doi.org/10.1155/2017/6753604

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/9789

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 96




Kleine Vorschau
Zusammenfassung: 
Conclusion. The development of a histological 3D model of the tympanic cavity visualizes the exact microanatomy of the sound conduction organ and is therefore essential for finite elements simulations and surgical training. Objectives. So far, no accurate histological 3D model of the sound conduction system existed in literature. For 3D reconstruction of the very fine structures inside and outside the auditory ossicles, a method based on histological slices allows a more differential analysis of both hard and soft tissues and could thus be superior to μCT. Method. A complete temporal bone was embedded in epoxy resin and microground in distances of about 34 μm. After photodocumentation of every plane, a 3D reconstruction was performed by using the Computer Aided Design (CAD) program Rhinoceros 5®. For comparison, a μCT of the same specimen resulted in a 3D model of the calcified structures in the middle ear. Results. The histological 3D model gives an excellent overview to all anatomical soft and bony tissues of the human auditory ossicles. Specifically the fine blood vessel system and the exact dimension of cartilage areas inside the ossicles can be illustrated much more precisely than with μCT data. The present technique also allows the evaluation of the fine connecting ligaments inside the tympanic cavity.
Lizenzbestimmungen: CC BY 4.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2017
Die Publikation erscheint in Sammlung(en):Fakultät für Maschinenbau

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 49 51,04%
2 image of flag of United States United States 15 15,62%
3 image of flag of China China 5 5,21%
4 image of flag of India India 4 4,17%
5 image of flag of Turkey Turkey 3 3,12%
6 image of flag of Russian Federation Russian Federation 3 3,12%
7 image of flag of No geo information available No geo information available 2 2,08%
8 image of flag of Poland Poland 2 2,08%
9 image of flag of United Kingdom United Kingdom 2 2,08%
10 image of flag of Thailand Thailand 1 1,04%
    andere 10 10,42%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.