What determines the differences found in forest edge flow between physical models and atmospheric measurements? - An LES study

Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Kanani, F.; Träumner, K.; Ruck, B.; Raasch, S.: What determines the differences found in forest edge flow between physical models and atmospheric measurements? - An LES study. In: Meteorologische Zeitschrift 23 (2014), Nr. 1, S. 33-49. DOI: https://doi.org/10.1127/0941-2948/2014/0542

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/945

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 327




Kleine Vorschau
Zusammenfassung: 
A recent study has shown that Doppler lidar is a state-of-the-art method to obtain spatially and temporally resolved flow fields in forest edge flow regimes. In that study, the general flow features observed by lidar were found to be similar to those detected above a physical tree model in a wind tunnel. But in pivotal details, for example regarding the absolute height and the inner structure of the internal boundary layer (IBL), significant differences were detected. The main objectives of this Large-Eddy Simulation (LES) study are to analyze these differences and to associate them to the meteorological and physical differences between the set-ups of the wind tunnel and the atmospheric measurement. This enables on the one hand a model evaluation for the LES and the physical model respectively, and on the other hand a better understanding of the results from the lidar measurements. Results from an LES with neutral stratification and without Coriolis force show a similar IBL structure as in the wind tunnel and represent well-known characteristics of forest edge flow. A variation of the forest density only marginally affects the IBL structure. The presence of a finite forest clearing as observed at the lidar site increases the turbulence level of the IBL, compared to a set-up with a quasi-infinite clearing like in the wind tunnel. Including Coriolis force further enhances the turbulence levels to values observed by lidar. An increasing thermal instability results in even higher turbulence levels. Hence, differences between wind tunnel and atmospheric measurements are mainly traced back to differences in the flow forcing and in the onflow conditions upstream of the forest edge. Furthermore, a statistical analysis reveals that insufficient averaging of the lidar data also contributes to the observed deviations from the wind tunnel results. Based on this analysis, we suggest that at least two and a half hours of measurements during equivalent atmospheric conditions are necessary to obtain a statistically representative mean IBL structure.
Lizenzbestimmungen: CC BY-NC 4.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2014
Die Publikation erscheint in Sammlung(en):Fakultät für Mathematik und Physik

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 234 71,56%
2 image of flag of United States United States 34 10,40%
3 image of flag of China China 13 3,98%
4 image of flag of United Kingdom United Kingdom 5 1,53%
5 image of flag of Sweden Sweden 4 1,22%
6 image of flag of Switzerland Switzerland 4 1,22%
7 image of flag of Hong Kong Hong Kong 3 0,92%
8 image of flag of Finland Finland 3 0,92%
9 image of flag of Argentina Argentina 3 0,92%
10 image of flag of Brazil Brazil 2 0,61%
    andere 22 6,73%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.