The influence of storage and heat treatment on a magnesium-based implant material: An in vitro and in vivo study

Download statistics - Document (COUNTER):

Bracht, K.; Angrisani, N.; Seitz, J.-M.; Eifler, Rainer; Weizbauer, A. Et al.: The influence of storage and heat treatment on a magnesium-based implant material: An in vitro and in vivo study. In: BioMedical Engineering Online 14 (2015), Nr. 1 , 92. DOI: https://doi.org/10.1186/s12938-015-0091-8

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/672

Selected time period:

year: 
month: 

Sum total of downloads: 300




Thumbnail
Abstract: 
Background: Magnesium alloys are recommended as a potential material for osteosynthesis. It is known that storage-induced property modifications can occur in materials like aluminum. Thus the aim of this study was to analyze the influence of storage durations of up to 48weeks on the biomechanical, structural, and degradation properties of the degradable magnesium alloy LAE442. Methods: Extruded implants (n=104; Ø 2.5mm×25mm) were investigated after storage periods of 0, 12, 24, and 48weeks in three different sub-studies: (I) immediately after the respective storage duration and after an additional (II) 56days of in vitro corrosion in simulated body fluid (SFB), and (III) 48weeks in vivo corrosion in a rabbit model, respectively. In addition, the influence of a T5-heat treatment (206°C for 15h in an argon atmosphere) was tested (n=26; 0week of storage). Evaluation was performed by three-point bending, scanning electron microscopy, radiography, μ-computed tomography, evaluation of the mean grain size, and contrast analysis of precipitations (such as aluminum or lithium). Results: The heat treatment induced a significant reduction in initial stability, and enhanced the corrosion resistance. In vivo experiments showed a good biocompatibility for all implants. During the storage of up to 48weeks, no significant changes occurred in the implant properties. Conclusions: LAE442 implants can be safely used after up to 48weeks of storage.
License of this version: CC BY 4.0 Unported
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2015
Appears in Collections:Fakultät für Maschinenbau

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 236 78.67%
2 image of flag of United States United States 29 9.67%
3 image of flag of China China 13 4.33%
4 image of flag of No geo information available No geo information available 4 1.33%
5 image of flag of India India 4 1.33%
6 image of flag of Spain Spain 3 1.00%
7 image of flag of Canada Canada 2 0.67%
8 image of flag of Sri Lanka Sri Lanka 1 0.33%
9 image of flag of Ireland Ireland 1 0.33%
10 image of flag of Belgium Belgium 1 0.33%
    other countries 6 2.00%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse