In vitro corrosion of ZEK100 plates in Hank's Balanced Salt Solution

Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Waizy, H.; Weizbauer, A.; Modrejewski, C.; Witte, F.; Windhagen, H. et al.: In vitro corrosion of ZEK100 plates in Hank's Balanced Salt Solution. In: BioMedical Engineering Online 11 (2012), 12. DOI: http://dx.doi.org/10.1186/1475-925X-11-12

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/605

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 335




Kleine Vorschau
Zusammenfassung: 
Background: In recent years magnesium alloys have been intensively investigated as potential resorbable materials with appropriate mechanical and corrosion properties. Particularly in orthopedic research magnesium is interesting because of its mechanical properties close to those of natural bone, the prevention of both stress shielding and removal of the implant after surgery.Methods: ZEK100 plates were examined in this in vitro study with Hank's Balanced Salt Solution under physiological conditions with a constant laminar flow rate. After 14, 28 and 42 days of immersion the ZEK100 plates were mechanically tested via four point bending test. The surfaces of the immersed specimens were characterized by SEM, EDX and XRD.Results: The four point bending test displayed an increased bending strength after 6 weeks immersion compared to the 2 week group and 4 week group. The characterization of the surface revealed the presence of high amounts of O, P and Ca on the surface and small Mg content. This indicates the precipitation of calcium phosphates with low solubility on the surface of the ZEK100 plates.Conclusions: The results of the present in vitro study indicate that ZEK100 is a potential candidate for degradable orthopedic implants. Further investigations are needed to examine the degradation behavior.
Lizenzbestimmungen: CC BY 2.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2012
Die Publikation erscheint in Sammlung(en):Fakultät für Maschinenbau

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 255 76,12%
2 image of flag of United States United States 38 11,34%
3 image of flag of China China 8 2,39%
4 image of flag of India India 6 1,79%
5 image of flag of No geo information available No geo information available 4 1,19%
6 image of flag of United Kingdom United Kingdom 3 0,90%
7 image of flag of Australia Australia 3 0,90%
8 image of flag of Russian Federation Russian Federation 2 0,60%
9 image of flag of Portugal Portugal 2 0,60%
10 image of flag of Czech Republic Czech Republic 1 0,30%
    andere 13 3,88%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.