Reproducibility of three different cardiac T2-mapping sequences at 1.5T and impact of cofactors on T2-relaxation times

Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Baessler, Bettina; Schaarschmidt, Frank; Schnackenburg, Bernhard; Stehning, Christian; Giolda, Agathe D. Et al.: Reproducibility of three different cardiac T2-mapping sequences at 1.5T and impact of cofactors on T2-relaxation times. In: Journal of Cardiovascular Magnetic Resonance 17 (2015), Suppl. 1, W12. DOI: http://dx.doi.org/10.1186/1532-429X-17-S1-W12

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/519

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 103




Kleine Vorschau
Zusammenfassung: 
Background: The high interindividual variability of myocardial T2 relaxation times appears to be one of the main challenges for the clinical application of cardiac T2-mapping. This study therefore aimed to evaluate potential underlying causes for this variability, analyzing the reproducibility of three different cardiac T2-mapping sequences and evaluating the influence of cofactors on T2 relaxation times. Methods: 30 healthy volunteers were examined three times on a clinical 1.5T scanner (scan 1: in the morning; scan 2: in the evening of the same day; scan 3: in the evening 2-3 weeks later). In each examination three different T2-mapping sequences were acquired at three slices in short axis view: Multi Echo Spin Echo (MESE), T2-prepared balanced Steady State Free Precession (T2prep; [1]) and Gradient Spin Echo (GraSE). Repeated measurements were performed for T2prep and GraSE. Segmented T2-maps were generated for each slice according to the AHA 17-segment model. Intra- and inter-observer reproducibility was tested in a subgroup of 10 randomly selected subjects, where manual ROIs were drawn independently to measure T2 values of each segment blinded to the other results. Results: Overall, we observed no systematic difference of T2 times due to diurnal effects and on long-term analysis. Differentiated analysis of variance components for all sequences, however, revealed a greater variance of T2 times over multiple time points than for repeated measurements within the same scan. Our study revealed a low intra-observer and inter-observer variability of manual ROI-definition and the acquired T2 times for each sequence. The coefficients of variation and intraclass correlation coefficients for intra-observer variability were: 1.3% and 0.89 for T2prep, 1.5% and 0.93 for GraSE, 3.1% and 0.83 for MESE; and for inter-observer variability: 3.3% and 0.66 for T2prep, 2.0% and 0.83 for GraSE, 3.6% and 0.77 for MESE. With respect to the influence of potential cofactors on T2 times, we observed a negative effect of the cofactor heart rate on mean T2 values, yet this effect proved to be not significant. Conversely, we found significant and positive relation between mean T2 times and the cofactors age, weight and height (p < 0.005, p < 0.05 and p < 0.05) in single linear regression models. Using multiple regression models, we observed significant relations between mean T2 times and age (p < 0.005), gender (p < 0.01), and either weight or height (p < 0.005), for given values of the remaining cofactors. Conclusions: Intra- and inter-observer reproducibility of all tested T2-mapping sequnces is high, thereby confirming previous studies. According to our study, the high interindividual variability of myocardial T2 relaxation times is most likely due to proband-related effects such as age, gender, weight and height and other cofactors intraindividually varying with time.
Lizenzbestimmungen: CC BY 4.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2015
Die Publikation erscheint in Sammlung(en):Naturwissenschaftliche Fakultät

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 64 62,14%
2 image of flag of United States United States 14 13,59%
3 image of flag of China China 13 12,62%
4 image of flag of Czech Republic Czech Republic 4 3,88%
5 image of flag of Russian Federation Russian Federation 3 2,91%
6 image of flag of Belgium Belgium 3 2,91%
7 image of flag of Taiwan Taiwan 1 0,97%
8 image of flag of Brazil Brazil 1 0,97%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.