Comparison of two prototypes of a magnetically adjustable glaucoma implant in rabbits

Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Schwerk, B.; Harder, L.; Windhövel, C.; Hewicker-Trautwein, M.; Wagner, A. et al.: Comparison of two prototypes of a magnetically adjustable glaucoma implant in rabbits. In: PLoS ONE 14 (2019), Nr. 4, e0215316. DOI: https://doi.org/10.1371/journal.pone.0215316

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/5062

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 126




Kleine Vorschau
Zusammenfassung: 
Glaucoma drainage devices are used in surgical glaucoma therapy. Success of controlling the intraocular pressure is limited due to fibrous implant encapsulation and fibrin coating on the implant which lead to drainage obstructions. An innovative implant with a magnetically adjustable valve was developed. The valve opening of the implant should eliminate inflammatory products from the outflow area and affect fibrous tissue formation to achieve a sufficient long-term aqueous humour outflow. Lifting of this valve should disturb cell adhesion by exerting mechanical forces. Before testing this hypothesis, the flow characteristics of glaucoma drainage devices, especially the outflow resistance by regular IOP, should be considered in a pilot study, as they are important in preventing too low postoperative intraocular pressure known as ocular hypotony. Therefore, two prototypes of the innovative implant differing in their valve area design were examined regarding their flow characteristics in a limited animal experiment lasting two weeks. Ten healthy New Zealand White rabbits were divided into two groups (A & B) with different implanted prototypes. Daily, tonometry and direct ophthalmoscopy were performed to assess the intraocular pressure and the inflammatory reaction of the eye. After two weeks, the rabbits were euthanised to evaluate the initially histological inflammatory reaction to the implant. In group A, one case of hypotony emerged. When considering the entire observation period, a highly statistically significant difference between the intraocular pressure in the operated eye and that in the control eye was detected in group A (p < 0.0001) in contrast to group B (p = 0.0063). The postoperative inflammatory signs decreased within two weeks. Histologically, a typical but low level foreign body reaction with macrophages and lymphocytes as well as mild to moderate fibrosis was seen after the short experimental period. Based on our tonometric results, prototype B seems to be the system of choice for further research assessing its long-term function and biocompatibility.
Lizenzbestimmungen: CC BY 4.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2019
Die Publikation erscheint in Sammlung(en):Fakultät für Mathematik und Physik

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 57 45,24%
2 image of flag of United States United States 31 24,60%
3 image of flag of China China 11 8,73%
4 image of flag of No geo information available No geo information available 6 4,76%
5 image of flag of Netherlands Netherlands 3 2,38%
6 image of flag of Nigeria Nigeria 3 2,38%
7 image of flag of France France 2 1,59%
8 image of flag of Spain Spain 2 1,59%
9 image of flag of Taiwan Taiwan 1 0,79%
10 image of flag of Philippines Philippines 1 0,79%
    andere 9 7,14%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.