Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Pfeifer, R.; Müller, C.W.; Hurschler, C.; Kaierle, S.; Wesling, V. et al.: Adaptable orthopedic shape memory implants. In: Procedia CIRP 5 (2013), S. 253-258. DOI: https://doi.org/10.1016/j.procir.2013.01.050

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/4575

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 186




Kleine Vorschau
Zusammenfassung: 
Apart from biological factors, the bone healing process strongly depends on the mechanical properties of the implant applied. The stiffness of the implant influences the micro-motion, one of the most important stimuli of the healing process within the fracture gap. Both, the "ideal" stiffness of an implant as well as the alteration of the mechanical properties over the course of healing are still a topic of research. Apart from biodegradable implants or "fixateur externe", it is not possible to alter the mechanical properties of the implants without second surgery. A "stiffness alterable" implant might have a positive impact on the healing process, e.g. a shorter healing time, an early ability to bear weight or the avoidance of a follow-on operation. In order to adapt the implant to the actual healing situation, nickel-titanium (NiTi) shape memory alloy (SMA) based implants that exhibit a variable middle piece were developed. Due to contactless induction heating, the transition temperature of the SMA is reached and triggers the one-way shape memory effect (SME). This leads to a slight modification of the second moment of inertia and to an adaption of the bending stiffness of the implant, respectively. Based on laser cutting and welding, NiTi-SMA based implants were manufactured by using thin, commercially available NiTi (thickness: 0.5 and 1.0 mm, transition temperature Af between 55-65°C) sheets. Depending on the implant design, 4-Point-Bending measurements showed feasible bending stiffness alterations around a range of 50 %, with regard to the original stiffness. Thereby, two approaches, increasing the bending stiffness and decreasing the bending stiffness, have been realized. Currently, the implant design is being adapted in order to meet the requirements for human applications. Custom made NiTi-SMA with a transition temperature around 45-50°C could continue to reduce the impact of the heating process and expand this concept to further medical applications, e.g. compression, anchoring or expansion of implants or devices.
Lizenzbestimmungen: CC BY-NC-ND 3.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2013
Die Publikation erscheint in Sammlung(en):An-Institute

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 83 44,62%
2 image of flag of United States United States 37 19,89%
3 image of flag of China China 12 6,45%
4 image of flag of India India 10 5,38%
5 image of flag of No geo information available No geo information available 6 3,23%
6 image of flag of Russian Federation Russian Federation 4 2,15%
7 image of flag of Singapore Singapore 3 1,61%
8 image of flag of Indonesia Indonesia 3 1,61%
9 image of flag of Hong Kong Hong Kong 3 1,61%
10 image of flag of France France 3 1,61%
    andere 22 11,83%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.