Abstract: 
The current design, and material implementation of the magnetic field sensing in the LISA Technology Package (LTP) on board LISA Pathfinder (LPF), is based on a set of 4 high-precision 3-axis fluxgate magnetometers. In order to avoid magnetic disturbances on the LTP proof masses (TM 's), originated by the sensors themselves, these are placed somewhat far from the TM's, which results in partial field information losses. We are currently investigating alternative magnetic sensing techniques, based on AMR (Anisotropic Magnetoresistive) devices. These are much smaller in size than fluxgates, therefore a more numerous array can be thought of for flight. In addition, there is a chance that they may be attached closer to the TM's, thereby enhancing magnetic field sensing spacial resolution. Several issues need to be addressed, such as real sensitivity (including electronics noise) and set/reset trigger procedures. A brief overview about the stability of the magnetic fields and gradients generated in the LTP by means of the coil will also be given. This paper show the latest results of our research.
License of this version: CC BY 3.0 Unported
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2009
Appears in Collections:An-Institute

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 54 41.86%
2 image of flag of China China 32 24.81%
3 image of flag of United States United States 28 21.71%
4 image of flag of Netherlands Netherlands 1 0.78%
5 image of flag of Japan Japan 1 0.78%
6 image of flag of Ireland Ireland 1 0.78%
7 image of flag of Hong Kong Hong Kong 1 0.78%
8 image of flag of United Kingdom United Kingdom 1 0.78%
9 image of flag of France France 1 0.78%
10 image of flag of Australia Australia 1 0.78%
    other countries 8 6.20%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse