Influence of the grain size on the in vivo degradation behaviour of the magnesium alloy LAE442

Download statistics - Document (COUNTER):

Ullmann, B.; Reifenrath, J.; Seitz, J.-M.; Bormann, D.; Meyer-Lindenberg, A.: Influence of the grain size on the in vivo degradation behaviour of the magnesium alloy LAE442. In: Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 227 (2013), Nr. 3, S. 317-326. DOI: https://doi.org/10.1177/0954411912471495

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/3016

Selected time period:

year: 
month: 

Sum total of downloads: 183




Thumbnail
Abstract: 
The aim of this study was to investigate the differences in the in vivo degradation behaviour of magnesium implants with various grain sizes and damaged surfaces. For this purpose, three different LAE442 magnesium implants were produced: cast, single and double extruded implants, in order to obtain different grain sizes. Furthermore, defects were positioned on the surfaces of some of the single extruded implants. The initial stability was determined. Four pins of each implant material were implanted into rabbits' tibiae and regularly clinically, radiologically and μ-computed tomographically investigated over a period of 27 weeks. Following explantation, investigations were carried out using stereo and scanning electron microscopy including energy-dispersive X-ray analyses. Weight and strength changes were measured. The double extruded implants possessing the finest grains exhibited the highest initial stability (179.18 N). These implants demonstrated the lowest in vivo corrosion rates (0.0134 mm/year) and the least radiologically visible changes. The highest corrosion rate was computed for the implants possessing damaged surfaces. Radiologically discernible bone changes occurred at almost the same time as implant changes for all groups. Based on these results, the aim should be to produce fine-grained magnesium-based alloys for resorbable implants and to avoid any surface damage. © IMechE 2013.
License of this version: Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. Dieser Beitrag ist aufgrund einer (DFG-geförderten) Allianz- bzw. Nationallizenz frei zugänglich.
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2013
Appears in Collections:Fakultät für Maschinenbau

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 127 69.40%
2 image of flag of United States United States 28 15.30%
3 image of flag of China China 11 6.01%
4 image of flag of Ireland Ireland 2 1.09%
5 image of flag of Belgium Belgium 2 1.09%
6 image of flag of Austria Austria 2 1.09%
7 image of flag of Taiwan Taiwan 1 0.55%
8 image of flag of Sweden Sweden 1 0.55%
9 image of flag of Portugal Portugal 1 0.55%
10 image of flag of Netherlands Netherlands 1 0.55%
    other countries 7 3.83%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse