Comparative in vitro study and biomechanical testing of two different magnesium alloys

Download statistics - Document (COUNTER):

Weizbauer, A.; Modrejewski, C.; Behrens, S.; Klein, H.; Helmecke, P. et al.: Comparative in vitro study and biomechanical testing of two different magnesium alloys. In: Journal of Biomaterials Applications 28 (2014), Nr. 8, S. 1264-1273. DOI: https://doi.org/10.1177/0885328213506758

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/2296

Selected time period:

year: 
month: 

Sum total of downloads: 195




Thumbnail
Abstract: 
In this in vitro study, magnesium plates of ZEK100 and MgCa0.8 alloy similar to common titanium alloy osteosynthesis plates were investigated as degradable biomedical materials with a focus on primary stability. Immersion tests were performed in Hank's Balanced Salt Solution at 37. The bending strength of the samples was determined using the four-point bending test according to ISO 9585:1990. The initial strength of the noncorroded ZEK100 plate was 11% greater than that of the MgCa0.8 plate; both were approximately 65% weaker than a titanium plate. The bending strength was determined after 48 and 96 h of immersion in Hank's Balanced Salt Solution; both magnesium alloys decreased by approximately 7% after immersion for 96 h. The degradation rate and the Mg2+ release of ZEK100 were lower than those of MgCa0.8. Strong pitting and filiform corrosion were observed in the MgCa0.8 samples after 96 h of immersion. The surface of the ZEK100 plates exhibited only small areas of filiform corrosion. The results of this in vitro study indicate that the ZEK100 alloy may be more suitable for biomedical applications. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
License of this version: Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. Dieser Beitrag ist aufgrund einer (DFG-geförderten) Allianz- bzw. Nationallizenz frei zugänglich.
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2014
Appears in Collections:Fakultät für Maschinenbau

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 89 45.64%
2 image of flag of United States United States 33 16.92%
3 image of flag of China China 27 13.85%
4 image of flag of No geo information available No geo information available 7 3.59%
5 image of flag of Malaysia Malaysia 6 3.08%
6 image of flag of India India 5 2.56%
7 image of flag of Russian Federation Russian Federation 3 1.54%
8 image of flag of Korea, Republic of Korea, Republic of 3 1.54%
9 image of flag of France France 2 1.03%
10 image of flag of Canada Canada 2 1.03%
    other countries 18 9.23%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse