Ezechieli, M.; Diekmann, J.; Weizbauer, A.; Becher, C.; Willbold, E. et al.: Biodegradation of a magnesium alloy implant in the intercondylar femoral notch showed an appropriate response to the synovial membrane in a rabbit model in vivo. In: Journal of Biomaterials Applications 29 (2014), Nr. 2, S. 291-302. DOI: https://doi.org/10.1177/0885328214523322

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/2293

Selected time period:

year: 
month: 

Sum total of downloads: 50




Thumbnail
Abstract: 
Degradable magnesium alloys are promising biomaterials for orthopedic applications. The aim of this study was to evaluate the potential effects on both the synovial membrane (synovialis) and the synovial fluid (synovia) of the degradation products of a MgYREZr-pin implanted in the intercondylar femoral notch in a rabbit model. Thirty-six animals were randomized into two groups (MgYREZr or Ti6Al4V alloy) of 18 animals each. Each group was then divided into three subgroups with implantation periods of 1, 4, and 12 weeks, with six animals in each subgroup. The initial inflammatory reaction caused by the surgical trauma declined after 12 weeks of implantation, and elucidated a progressive recovery of the synovial membrane. Compared with control Ti6Al4V pins, there were no significant differences between the groups. However, after 12 weeks, recovery of the synovial membrane was more advanced in the titanium group, in which 92% showed no signs of synovitis, than in the magnesium group. A cytotoxicity test with L929 cells and human osteoblasts (HOB) was also conducted, according to EN ISO 10993-5/12, and no toxic leachable products were observed after 24 h of incubation. In conclusion, the MgYREZr alloy seems to be a suitable material for intra-articular degradable implants. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
License of this version: Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. Dieser Beitrag ist aufgrund einer (DFG-geförderten) Allianz- bzw. Nationallizenz frei zugänglich.
Document Type: article
Publishing status: publishedVersion
Issue Date: 2014
Appears in Collections:Fakultät für Maschinenbau

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 31 62.00%
2 image of flag of China China 5 10.00%
3 image of flag of United States United States 4 8.00%
4 image of flag of Japan Japan 2 4.00%
5 image of flag of India India 2 4.00%
6 image of flag of Taiwan Taiwan 1 2.00%
7 image of flag of Slovenia Slovenia 1 2.00%
8 image of flag of Russian Federation Russian Federation 1 2.00%
9 image of flag of Pakistan Pakistan 1 2.00%
10 image of flag of Iran, Islamic Republic of Iran, Islamic Republic of 1 2.00%
    other countries 1 2.00%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse