In situ optical coherence tomography of percutaneous implant-tissue interfaces in a murine model

Download statistics - Document (COUNTER):

Donner, Sabine; Mueller, Oliver; Witte, Frank; Bartsch, Ivonne; Willbold, Elmar; Ripken, Tammo; Heisterkamp, Alexander; Rosenhahn, Bodo; Krueger, Alexander: In situ optical coherence tomography of percutaneous implant-tissue interfaces in a murine model. In: Biomedical Engineering-Biomedizinische Technik 58 (2013), Nr. 4, S. 359-367. DOI: http://dx.doi.org/10.1515/bmt-2012-0044

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/202

Selected time period:

year: 
month: 

Sum total of downloads: 483




Thumbnail
Abstract: 
Novel surface coatings of percutaneous implants need to be tested in biocompatibility studies. The use of animal models for testing usually involves numerous lethal biopsies for the analysis of the implant-tissue interface. In this study, optical coherence tomography (OCT) was used to monitor the reaction of the skin to a percutaneous implant in an animal model of hairless but immunocompetent mice. In vivo optical biopsies with OCT were taken at days 7 and 21 after implantation and post mortem on the day of noticeable inflammation. A Fourier-domain OCT was programmed for spoke pattern scanning schemes centered at the implant midpoint to reduce motion artifacts during in vivo imaging. Image segmentation allowed the automatic detection and morphometric analysis of the skin contour and the subcutaneous implant anchor. On the basis of the segmentation, the overall refractive index of the tissue within one OCT data set was estimated as a free parameter of a fitting algorithm, which corrects for the curved distortion of the planar implant base in the OCT images. OCT in combination with the spoke scanning scheme and image processing provided time-resolved three-dimensional optical biopsies around the implants to assess tissue morphology.
License of this version: Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. Dieser Beitrag ist aufgrund einer (DFG-geförderten) Allianz- bzw. Nationallizenz frei zugänglich.
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2013-05-17
Appears in Collections:Naturwissenschaftliche Fakultät

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 378 78.26%
2 image of flag of United States United States 72 14.91%
3 image of flag of China China 8 1.66%
4 image of flag of United Kingdom United Kingdom 3 0.62%
5 image of flag of France France 3 0.62%
6 image of flag of Netherlands Netherlands 2 0.41%
7 image of flag of India India 2 0.41%
8 image of flag of Finland Finland 2 0.41%
9 image of flag of Brazil Brazil 2 0.41%
10 image of flag of Ireland Ireland 1 0.21%
    other countries 10 2.07%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse