Sensor noise in LISA Pathfinder: Laser frequency noise and its coupling to the optical test mass readout

Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Armano, M.; Audley, H.; Baird, J.; Binetruy, P.; Born, M. et al.: Sensor noise in LISA Pathfinder: Laser frequency noise and its coupling to the optical test mass readout. In: Physical Review D 109 (2024), Nr. 4, 042003. DOI: https://doi.org/10.1103/physrevd.109.042003

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/16824

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 11




Kleine Vorschau
Zusammenfassung: 
The LISA Pathfinder (LPF) mission successfully demonstrated the feasibility of the technology needed for the future space borne gravitational wave observatory LISA. A key subsystem under study was the laser interferometer, which measured the changes in relative distance in between two test masses (TMs). It achieved a sensitivity of 32.0+2.4−1.7  fm/√Hz, which was significantly better than the prelaunch tests. This improved performance allowed direct observation of the influence of laser frequency noise in the readout. The differences in optical path lengths between the measurement and reference beams in the individual interferometers of our setup determined the level of this undesired readout noise. Here, we discuss the dedicated experiments performed on LPF to measure these differences with high precision. We reached differences in path length difference between (368±5)  μm and (329.6±0.9)  μm which are significantly below the required level of 1 mm or 1000  μm. These results are an important contribution to our understanding of the overall sensor performance. Moreover, we observed varying levels of laser frequency noise over the course of the mission. We provide evidence that these do not originate from the laser frequency stabilization scheme which worked as expected. Therefore, this frequency stabilization would be applicable to other missions with similar laser frequency stability requirements.
Lizenzbestimmungen: CC BY 4.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2024
Die Publikation erscheint in Sammlung(en):An-Institute

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 5 45,45%
2 image of flag of United States United States 4 36,36%
3 image of flag of Indonesia Indonesia 1 9,09%
4 image of flag of China China 1 9,09%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.