Mönster, A.; Villain, L.; Scheper, T.; Beutel, S.: One-step-purification of penicillin G amidase from cell lysate using ion-exchange membrane adsorbers. In: Journal of Membrane Science 444 (2013), S. 359-364. DOI: https://doi.org/10.1016/j.memsci.2013.05.054
Zusammenfassung: | |
This study describes the purification of penicillin G amidase (PGA) by ion exchange membrane adsorbers in a one-step-process. Preliminary experiments with high-throughput screening devices in microliter scale (8-strip modules) were performed to find suitable purification strategy and appropriate ion exchange ligands as well as basic process conditions for binding and elution. Best purification results were achieved by strong cation-exchange (S-) membrane adsorbers loaded with 2ml/min enzyme solution at pH 6.0 and eluted at pH 6.0 with 0.05M NaCl, which led to a high yield of bound PGA (98%) without any visible remains of host cell proteins and with a residual enzyme activity of 80-85%. The binding of PGA to the S-membrane was further investigated in an upscaling to milliliter scale with LP15 modules and breakthrough curves were determined by varying the flow rates: the PGA-binding to S-membrane adsorbers is independent of the flow rate. Dynamic binding capacities were estimated to be 0.69mg PGA/cm2 (25.5mg/ml) for 10% breakthrough respectively 0.95mg/cm2 (35.2mg/ml) for 100% breakthrough. Finally, real cell lysate samples from Escherichia coli culture containing PGA were processed under the found optimal conditions. Despite exceeded loading PGA was isolated from this complex mixture successfully fourfold concentrated and with a purification factor of 101.3 and a resulting specific activity of 4.97U/mg. | |
Lizenzbestimmungen: | CC BY-NC-ND 4.0 Unported |
Publikationstyp: | Article |
Publikationsstatus: | acceptedVersion |
Erstveröffentlichung: | 2013 |
Die Publikation erscheint in Sammlung(en): | Naturwissenschaftliche Fakultät |
Pos. | Land | Downloads | ||
---|---|---|---|---|
Anzahl | Proz. | |||
1 | Germany | 223 | 50,34% | |
2 | United States | 48 | 10,84% | |
3 | India | 29 | 6,55% | |
4 | Portugal | 15 | 3,39% | |
5 | Indonesia | 13 | 2,93% | |
6 | China | 12 | 2,71% | |
7 | Vietnam | 11 | 2,48% | |
8 | Malaysia | 8 | 1,81% | |
9 | Russian Federation | 7 | 1,58% | |
10 | France | 6 | 1,35% | |
andere | 71 | 16,03% |
Hinweis
Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.