Negative Reactant Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS)

Download statistics - Document (COUNTER):

Allers, M.; Kirk, A.T.; Timke, B.; Erdogdu, D.; Wissorf, W. et al.: Negative Reactant Ion Formation in High Kinetic Energy Ion Mobility Spectrometry (HiKE-IMS). In: Journal of the American Society for Mass Spectrometry : JASMS online 31 (2020), Nr. 9, S. 1861-1874. DOI: https://doi.org/10.1021/jasms.0c00126

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/10983

Selected time period:

year: 
month: 

Sum total of downloads: 132




Thumbnail
Abstract: 
Due to the operation at background pressures between 10-40 mbar and high reduced electric field strengths of up to 120 Td, the ion–molecule reactions in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) differ from those in classical ambient pressure IMS. In the positive ion polarity mode, the reactant ions H+(H2O)n, O2+(H2O)n, and NO+(H2O)n are observed in the HiKE-IMS. The relative abundances of these reactant ion species significantly depend on the reduced electric field strength in the reaction region, the operating pressure, and the water concentration in the reaction region. In this work, the formation of negative reactant ions in HiKE-IMS is investigated in detail. On the basis of kinetic and thermodynamic data from the literature, the processes resulting in the formation of negative reactant ions are kinetically modeled. To verify the model, we present measurements of the negative reactant ion population in the HiKE-IMS and its dependence on the reduced electric field strength as well as the water and carbon dioxide concentrations in the reaction region. The ion species underlying individual peaks in the ion mobility spectrum are identified by coupling the HiKE-IMS to a time-of-flight mass spectrometer (TOF-MS) using a simple gated interface that enables the transfer of selected peaks of the ion mobility spectrum into the TOF-MS. Both the theoretical model as well as the experimental data suggest the predominant generation of the oxygen-based ions O–, OH–, O2–, and O3– in purified air containing 70 ppmv of water and 30 ppmv of carbon dioxide. Additionally, small amounts of NO2– and CO3– are observed. Their relative abundances highly depend on the reduced electric field strength as well as the water and carbon dioxide concentration. An increase of the water concentration in the reaction region results in the generation of OH– ions, whereas increasing the carbon dioxide concentration favors the generation of CO3– ions, as expected.
License of this version: Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden.
Document Type: Article
Publishing status: acceptedVersion
Issue Date: 2020-07-16
Appears in Collections:Fakultät für Elektrotechnik und Informatik

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 58 43.94%
2 image of flag of United States United States 23 17.42%
3 image of flag of China China 17 12.88%
4 image of flag of Korea, Republic of Korea, Republic of 4 3.03%
5 image of flag of Russian Federation Russian Federation 3 2.27%
6 image of flag of India India 3 2.27%
7 image of flag of Canada Canada 3 2.27%
8 image of flag of Japan Japan 2 1.52%
9 image of flag of Iran, Islamic Republic of Iran, Islamic Republic of 2 1.52%
10 image of flag of United Kingdom United Kingdom 2 1.52%
    other countries 15 11.36%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository