Reliability and suitability of physiological exercise response and recovery markers

Downloadstatistik des Dokuments (Auswertung nach COUNTER):

Reichel, T.; Boßlau, T.K.; Palmowski, J.; Eder, K.; Ringseis, R. et al.: Reliability and suitability of physiological exercise response and recovery markers. In: Scientific Reports 10 (2020), Nr. 1, 11924. DOI: https://doi.org/10.1038/s41598-020-69280-9

Version im Repositorium

Zum Zitieren der Version im Repositorium verwenden Sie bitte diesen DOI: https://doi.org/10.15488/10951

Zeitraum, für den die Download-Zahlen angezeigt werden:

Jahr: 
Monat: 

Summe der Downloads: 92




Kleine Vorschau
Zusammenfassung: 
There is currently insufficient evidence about the reliable quantification of exercise load and athlete’s recovery management for monitoring training processes. Therefore, this test–retest study investigated the reliability of various subjective, muscle force, and blood-based parameters in order to evaluate their suitability for monitoring exercise and recovery cycles. 62 subjects completed two identical 60-min continuous endurance exercise bouts intermitted by a four-week recovery period. Before, immediately after, three, and 24 h after each exercise bout, analysis of parameters were performed. Significant changes over time were found for rating of perceived exertion (RPE), multidimensional mood state questionnaire (MDMQ), maximum voluntary contraction parameters (MVCs), and blood-based biomarkers (p < 0.05). Excellent reliability was calculated for MVCs, mean corpuscular volume and 5-bound distance (ICC > 0.90). A good reliability was found for thiobarbituric acid reactive substances (TBARS) (ICC = 0.79) and haematological markers (ICC = 0.75–0.86). For RPE, MDMQ, interleukin (IL-) 1RA, IL-6, IL-8, IL-15, cortisol, lactate dehydrogenase (LDH), creatine kinase (CK) only moderate reliability was found (ICC < 0.75). Significant associations for IL1-RA and CK to MVC were found. The excellent to moderate reliability of TBARS, LDH, IL-1RA, six measured haematological markers, MVCs and MDMQ implicate their suitability as physiological exercise response and recovery markers for monitoring athletes’ load management. © 2020, The Author(s).
Lizenzbestimmungen: CC BY 4.0 Unported
Publikationstyp: Article
Publikationsstatus: publishedVersion
Erstveröffentlichung: 2020
Die Publikation erscheint in Sammlung(en):Philosophische Fakultät

Verteilung der Downloads über den gewählten Zeitraum:

Herkunft der Downloads nach Ländern:

Pos. Land Downloads
Anzahl Proz.
1 image of flag of Germany Germany 38 41,30%
2 image of flag of United States United States 20 21,74%
3 image of flag of No geo information available No geo information available 17 18,48%
4 image of flag of China China 5 5,43%
5 image of flag of Turkey Turkey 1 1,09%
6 image of flag of Portugal Portugal 1 1,09%
7 image of flag of Latvia Latvia 1 1,09%
8 image of flag of Iran, Islamic Republic of Iran, Islamic Republic of 1 1,09%
9 image of flag of India India 1 1,09%
10 image of flag of Australia Australia 1 1,09%
    andere 6 6,52%

Weitere Download-Zahlen und Ranglisten:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.