IMS Instrumentation I : Isolated data acquisition for ion mobility spectrometers with grounded ion sources

Download statistics - Document (COUNTER):

Lippmann, M.; Kirk, A.T.; Hitzemann, M.; Zimmermann, S.: IMS Instrumentation I : Isolated data acquisition for ion mobility spectrometers with grounded ion sources. In: International journal for ion mobility spectrometry : official publication of the International Society for Ion Mobility Spectrometry 23 (2020), S. 69-74. DOI: https://doi.org/10.1007/s12127-020-00260-5

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/10862

Selected time period:

year: 
month: 

Sum total of downloads: 126




Thumbnail
Abstract: 
The drift voltage required for operating ion mobility spectrometers implies high voltage isolation of either the ion source or the detector. Typically, the detector is grounded due to the sensitivity of the small ion currents to interferences and thus higher requirements for signal integrity than the ion source. However, for certain ion sources, such as non-radioactive electron emitters or electrospray ionization sources, or for coupling with other instruments, such as gas or liquid chromatographs, a grounded ion source is beneficial. In this paper, we present an isolated data acquisition interface using a 16 bit, 250 kilosamples per second analog to digital converter and fiber optic transmitters and receivers. All spectra recorded via this new data acquisition interface and with a grounded ion source show the same peak shapes and noise when compared with a grounded detector, allowing additional freedom in design. © 2020, The Author(s).
License of this version: CC BY 4.0 Unported
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2020
Appears in Collections:Fakultät für Elektrotechnik und Informatik

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 70 55.56%
2 image of flag of United States United States 19 15.08%
3 image of flag of China China 16 12.70%
4 image of flag of United Kingdom United Kingdom 4 3.17%
5 image of flag of Indonesia Indonesia 3 2.38%
6 image of flag of France France 3 2.38%
7 image of flag of Canada Canada 3 2.38%
8 image of flag of Vietnam Vietnam 1 0.79%
9 image of flag of Hong Kong Hong Kong 1 0.79%
10 image of flag of Australia Australia 1 0.79%
    other countries 5 3.97%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse