Calibration routine for a telecentric stereo vision system considering affine mirror ambiguity

Download statistics - Document (COUNTER):

Beermann, R.; Quentin, L.; Kästner, M.; Reithmeier, E.: Calibration routine for a telecentric stereo vision system considering affine mirror ambiguity. In: Optical Engineering 59 (2020), Nr. 5, 054104. DOI: https://doi.org/10.1117/1.OE.59.5.054104

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/10315

Selected time period:

year: 
month: 

Sum total of downloads: 274




Thumbnail
Abstract: 
A robust calibration approach for a telecentric stereo camera system for three-dimensional (3-D) surface measurements is presented, considering the effect of affine mirror ambiguity. By optimizing the parameters of a rigid body transformation between two marker planes and transforming the two-dimensional (2-D) data into one coordinate frame, a 3-D calibration object is obtained, avoiding high manufacturing costs. Based on the recent contributions in the literature, the calibration routine consists of an initial parameter estimation by affine reconstruction to provide good start values for a subsequent nonlinear stereo refinement based on a Levenberg–Marquardt optimization. To this end, the coordinates of the calibration target are reconstructed in 3-D using the Tomasi–Kanade factorization algorithm for affine cameras with Euclidean upgrade. The reconstructed result is not properly scaled and not unique due to affine ambiguity. In order to correct the erroneous scaling, the similarity transformation between one of the 2-D calibration plane points and the corresponding 3-D points is estimated. The resulting scaling factor is used to rescale the 3-D point data, which then allows in combination with the 2-D calibration plane data for a determination of the start values for the subsequent nonlinear stereo refinement. As the rigid body transformation between the 2-D calibration planes is also obtained, a possible affine mirror ambiguity in the affine reconstruction result can be robustly corrected. The calibration routine is validated by an experimental calibration and various plausibility tests. Due to the usage of a calibration object with metric information, the determined camera projection matrices allow for a triangulation of correctly scaled metric 3-D points without the need for an individual camera magnification determination.
License of this version: CC BY 4.0 Unported
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2020
Appears in Collections:Fakultät für Maschinenbau

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 91 33.21%
2 image of flag of United States United States 45 16.42%
3 image of flag of China China 16 5.84%
4 image of flag of Russian Federation Russian Federation 12 4.38%
5 image of flag of Netherlands Netherlands 12 4.38%
6 image of flag of United Kingdom United Kingdom 12 4.38%
7 image of flag of No geo information available No geo information available 8 2.92%
8 image of flag of India India 8 2.92%
9 image of flag of Czech Republic Czech Republic 6 2.19%
10 image of flag of Australia Australia 5 1.82%
    other countries 59 21.53%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse