Transportable setup for amplifier phase fidelity measurements

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/408
dc.identifier.uri http://www.repo.uni-hannover.de/handle/123456789/431
dc.contributor.author Troebs, Michael
dc.contributor.author Bogan, C.
dc.contributor.author Barke, S.
dc.contributor.author Kuehn, G.
dc.contributor.author Reiche, J.
dc.contributor.author Heinzel, Gerhard
dc.contributor.author Danzmann, Karsten
dc.date.accessioned 2016-08-12T08:59:22Z
dc.date.available 2016-08-12T08:59:22Z
dc.date.issued 2015
dc.identifier.citation Troebs, M.; Bogan, C.; Barke, S.; Kuehn, G.; Reiche, J. et. al.: Transportable setup for amplifier phase fidelity measurements. In: Journal of Physics Conference Series 610 (2015), 12041. DOI: http://dx.doi.org/10.1088/1742-6596/610/1/012041
dc.description.abstract One possible laser source for the Laser Interferometer Space Antenna (LISA) consists of an Ytterbium-doped fiber amplifier originally developed for inter-satellite communication, seeded by the laser used for the technology demonstrator mission LISA Pathfinder. LISA needs to transmit clock information between its three spacecraft to correct for phase noise between the clocks on the individual spacecraft. For this purpose phase modulation sidebands at GHz frequencies will be imprinted on the laser beams between spacecraft. Differential phase noise between the carrier and a sideband introduced within the optical chain must be very low. We report on a transportable setup to measure the phase fidelity of optical amplifiers. eng
dc.description.sponsorship DFG/EXC/QUEST
dc.description.sponsorship DLR/50OQ1301
dc.description.sponsorship DLR/50OQ0601
dc.language.iso eng
dc.publisher Bristol : IOP Publishing Ltd.
dc.relation.ispartofseries Journal of Physics Conference Series 610 (2015)
dc.rights CC BY 3.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/3.0/de/
dc.subject interferometer eng
dc.subject lisa eng
dc.subject.classification Konferenzschrift ger
dc.subject.ddc 500 | Naturwissenschaften ger
dc.subject.ddc 530 | Physik ger
dc.title Transportable setup for amplifier phase fidelity measurements eng
dc.type Article
dc.type Text
dc.relation.essn 1742-6596
dc.relation.issn 1742-6588
dc.relation.doi http://dx.doi.org/10.1088/1742-6596/610/1/012041
dc.bibliographicCitation.volume 610
dc.bibliographicCitation.firstPage 12041
dc.description.version publishedVersion
tib.accessRights frei zug�nglich