Multi-criteria comparison of various drinking water installations for low-temperature supply systems in apartments

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/17132
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/17260
dc.contributor.author Pärisch, Peter
dc.contributor.author Distelhoff, Mark
dc.contributor.author Keuler, Jonas
dc.contributor.author Lampe, Carsten
dc.contributor.author Graf, Christopher
dc.contributor.author Cadenbach, Anna
dc.date.accessioned 2024-04-18T06:09:21Z
dc.date.available 2024-04-18T06:09:21Z
dc.date.issued 2023
dc.identifier.citation Pärisch, P.; Distelhoff, M.; Keuler, J.; Lampe, C.; Graf, C. et al.: Multi-criteria comparison of various drinking water installations for low-temperature supply systems in apartments. In: Journal of Physics: Conference Series 2600 (2023), Nr. 2, 022022. DOI: https://doi.org/10.1088/1742-6596/2600/2/022022
dc.description.abstract Rules to prevent from legionnaires disease gain importance as the building sector, esp. multi-family houses, needs to be decarbonized with temperature sensitive heat pumps. As legionella grow often in the peripheries of the pipe networks, we carried out dynamic simulations with TRNSYS of four different piping designs with composite pipes inside a reference apartment (T-piece, in-series, ring and a mix of T-piece for potable hot water (PWH) and ring for potable cold water (PWC)). We applied PWH and PWC tapping profiles for each tap, investigated two different supply temperatures of potable hot water 60 °C and 45 °C, and compared the results using hygienic, comfort and energy efficiency performance indicators. Based on the indicators and the boundary conditions used, classical T-piece and the mix installation show the best results, followed by series and ring, especially when using decentral water heaters with 45 °C. eng
dc.language.iso eng
dc.publisher Bristol : IOP Publ.
dc.relation.ispartofseries Journal of Physics: Conference Series 2600 (2023), Nr. 2
dc.rights CC BY 3.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/3.0
dc.subject Apartment houses eng
dc.subject Energy efficiency eng
dc.subject Temperature eng
dc.subject Buildings sector eng
dc.subject Heat pumps eng
dc.subject Hot water eng
dc.subject Legionellae eng
dc.subject Legionnaire's disease eng
dc.subject Lows-temperatures eng
dc.subject Multi-criteria eng
dc.subject Multi-Criterion eng
dc.subject Supply system eng
dc.subject Temperature sensitive eng
dc.subject Potable water eng
dc.subject.classification Konferenzschrift ger
dc.subject.ddc 530 | Physik
dc.title Multi-criteria comparison of various drinking water installations for low-temperature supply systems in apartments eng
dc.type Article
dc.type Text
dc.relation.essn 1742-6596
dc.relation.issn 1742-6588
dc.relation.doi https://doi.org/10.1088/1742-6596/2600/2/022022
dc.bibliographicCitation.issue 2
dc.bibliographicCitation.volume 2600
dc.bibliographicCitation.firstPage 022022
dc.description.version publishedVersion eng
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

  • An-Institute
    Frei zugängliche Publikationen aus An-Instituten der Leibniz Universität Hannover

Zur Kurzanzeige

 