In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/16614
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/16741
dc.contributor.author Kaufmann, A.B.
dc.contributor.author Lazarov, M.
dc.contributor.author Kiefer, S.
dc.contributor.author Majzlan, J.
dc.contributor.author Weyer, S.
dc.date.accessioned 2024-03-15T10:02:53Z
dc.date.available 2024-03-15T10:02:53Z
dc.date.issued 2021
dc.identifier.citation Kaufmann, A.B.; Lazarov, M.; Kiefer, S.; Majzlan, J.; Weyer, S.: In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS. In: Journal of Analytical Atomic Spectrometry 36 (2021), Nr. 7, S. 1554-1567. DOI: https://doi.org/10.1039/d1ja00089f
dc.description.abstract Here we present a method for in situ determination of stable antimony (Sb) isotope compositions by ultraviolet (UV)-femtosecond-laser-ablation-multi-collector-ICP-MS (fs-LA-MC-ICP-MS). Metallic antimony and a number of Sb minerals (stibnite, senarmontite, chalcostibite, tetrahedrite, boulangerite, bournonite, zinkenite, pyrargyrite and dyscrasite) have been investigated. In order to verify the results of the in situ method, LA-MC-ICP-MS measurements were compared with solution MC-ICP-MS analyses on two chemically homogeneous stibnite samples and Sb metal. The internal precision of in situ measurements was better than 0.045‰. The long-term reproducibility for these three materials was better than 0.1‰. These results imply that any of these three materials may be used as an in situ Sb isotope standard. All δ123Sb values were determined by applying a standard-sample bracketing protocol and mass bias correction using Sn (NIST SRM 3161a standard solution) isotope ratios. Since no certified Sb isotope standard is currently available, in situ isotope analyses were performed in bracketing to a stibnite in-house standard and subsequently recalculated relative to NIST SRM 3102a. Matrix effects from Cu, Pb, Ag, Fe and Zn on the natural mineral Sb isotope ratios were insignificant. The mass interference of 123Te on 123Sb can only precisely be corrected for materials with Te/Sb ≤ 0.2. The LA and solution analyses of δ123Sb homogeneous zinkenite, dyscrasite and pyrargyrite agree excellently with each other. Senarmontite shows more variable δ123Sb at small scales, determined with LA-MC-ICP-MS, but homogeneous δ123Sb determined by solution analyses with a small offset between solution and LA analyses. Other minerals, like boulangerite, show heterogeneous δ123Sb (≈0.5‰) for both solution and LA analyses. Overall, these results demonstrate that fs-LA-MC-ICP-MS is suitable to measure Sb isotopic ratios in Sb-rich sulfides, sulfosalts and oxides (excluding Sb tellurides) with a precision better than 0.1‰ and a spatial resolution of ≈30 μm. Thus, it may be used as a tool to analyse spatially resolved Sb isotope composition at the mineral or even sub-mineral scale, e.g. to address the processes of ore formation or Sb redistribution in near-surface environments. eng
dc.language.iso eng
dc.publisher Cambridge : ChemSoc
dc.relation.ispartofseries Journal of Analytical Atomic Spectrometry 36 (2021), Nr. 7
dc.rights CC BY 3.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/3.0
dc.subject Femtosecond lasers eng
dc.subject Inductively coupled plasma mass spectrometry eng
dc.subject Isotopes eng
dc.subject Laser ablation eng
dc.subject Mass spectrometers eng
dc.subject Ores eng
dc.subject Oxide minerals eng
dc.subject Solution mining eng
dc.subject Sulfide minerals eng
dc.subject Sulfur compounds eng
dc.subject Tellurium compounds eng
dc.subject Ultraviolet lasers eng
dc.subject In-situ measurement eng
dc.subject Isotope compositions eng
dc.subject Mass bias correction eng
dc.subject Mass interferences eng
dc.subject Reproducibilities eng
dc.subject Spatial resolution eng
dc.subject Spatially resolved eng
dc.subject Standard solutions eng
dc.subject Antimony compounds eng
dc.subject.ddc 540 | Chemie
dc.title In situ determination of antimony isotope ratios in Sb minerals by femtosecond LA-MC-ICP-MS eng
dc.type Article
dc.type Text
dc.relation.essn 1364-5544
dc.relation.issn 0267-9477
dc.relation.doi https://doi.org/10.1039/d1ja00089f
dc.bibliographicCitation.issue 7
dc.bibliographicCitation.volume 36
dc.bibliographicCitation.firstPage 1554
dc.bibliographicCitation.lastPage 1567
dc.description.version publishedVersion eng
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken