Improved Calibration Procedure for Wireless Inertial Measurement Units without Precision Equipment

Zur Kurzanzeige

dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/13806
dc.identifier.uri https://doi.org/10.15488/13696
dc.contributor.author Webering, Fritz
dc.contributor.author Kleinjohann, Sarah
dc.contributor.author Stanislawski, Nils
dc.contributor.author Blume, Holger
dc.date.accessioned 2023-05-16T13:58:01Z
dc.date.available 2023-05-16T13:58:01Z
dc.date.issued 2022
dc.identifier.citation Webering, F.; Kleinjohann, S.; Stanislawski, N.; Blume, H.: Improved Calibration Procedure for Wireless Inertial Measurement Units without Precision Equipment. ArXiv, Preprint, 2022, 5 S. DOI: https://doi.org/10.48550/arXiv.2207.04801
dc.description.abstract Inertial measurement units (IMUs) are used in medical applications for many different purposes. However, an IMU's measurement accuracy can degrade over time, entailing re-calibration. In their 2014 paper, Tedaldi et al. presented an IMU calibration method that does not require external precision equipment or complex procedures. This allows end-users or personnel without expert knowledge of inertial measurement to re-calibrate the sensors by placing them in several suitable but not precisely defined orientations. In this work, we present several improvements to Tedaldi's method, both on the algorithmic level and the calibration procedure: adaptions for low noise accelerometers, a calibration helper object, and packet loss compensation for wireless calibration. We applied the modified calibration procedure to our custom-built IMU platform and verified the consistency of results across multiple calibration runs. In order to minimize the time needed for re-calibration, we analyzed how the calibration result accuracy degrades when fewer calibration orientations are used. We found that N=12 different orientations are sufficient to achieve a very good calibration, and more orientations yielded only marginal improvements. This is a significant improvement compared to the 37 to 50 orientations recommended by Tedaldi. Thus, we were reduced the time required to calibrate a single IMU from ca. 5 minutes to less than 2 minutes without sacrificing any meaningful calibration accuracy. eng
dc.language.iso eng
dc.publisher [Erscheinungsort nicht ermittelbar] : ArXiv
dc.rights Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden.
dc.subject inertial measurement unit eng
dc.subject calibration eng
dc.subject wireless eng
dc.subject.ddc 621,3 | Elektrotechnik, Elektronik
dc.title Improved Calibration Procedure for Wireless Inertial Measurement Units without Precision Equipment eng
dc.type Article
dc.type Text
dc.relation.doi https://doi.org/10.48550/arXiv.2207.04801
dcterms.extent 5 S.
dc.description.version submittedVersion eng