Improving ion mobility spectrometer sensitivity through an optimized sample gas flow

Zur Kurzanzeige

dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/13292
dc.identifier.uri https://doi.org/10.15488/13185
dc.contributor.author Kirk, Ansgar T. eng
dc.contributor.author Kueddelsmann, Maximilian J. eng
dc.contributor.author Zimmermann, Stefan eng
dc.date.accessioned 2023-01-04T17:22:53Z
dc.date.available 2023-01-04T17:22:53Z
dc.date.issued 2023
dc.identifier.citation Kirk, A.T.; Kueddelsmann, N.J.; Zimmermann, S.: Improving ion mobility spectrometer sensitivity through an optimized sample gas flow. Poster Presentation at the International Conference on Ion Mobility Spectrometry 2020, online. Hannover : Institutionelles Repositorium der Leibniz Universität Hannover, 2023. DOI: https://doi.org/10.15488/13185 eng
dc.description.abstract The gas flow transporting the sample molecules into and through the reaction region of an ion mobility spectrometer (IMS) has a profound influence on its response, determining both sensitivity and response time. In the past, several key improvements relating to the sample gas flow have been reported, for example the use of a drift gas counter-flow by Baim et al., on-axis sample introduction by St. Louis et al. or side-flow sample introduction by Lee et al. Here, we also aim to optimize the sample gas flow inside an IMS equipped with an extended field switching shutter. By introducing a laminar flow curtain orthogonal to the drift direction through the small field-free reaction region, a significant increase in sensitivity and decrease in response time could be achieved for an already extremely sensitive IMS. The constructed ion source is equipped with both a 10.6 eV UV lamp to initiate direct photo ionization (APPI) and a low-energy X-ray source to initiate chemical ionization (APCI). For an averaging time of just one second during continuous sample introduction, limits of detection in the pptv-range using APPI and in the ppqv-range using chemical ionization (APCI) are reached. For pulsed sample introduction, as in GC-IMS, limits of detection are currently under investigation. However, rise and fall times of less than a second have already been observed for volatile organic compounds at a system temperature of 45 °C. When using APCI, the combination of extremely high sensitivity with fast response times is especially suitable as an ultra-sensitive, orthogonal GC detector for analyzing complex mixtures. When using APPI, the combination of improved linearity with still high sensitivity is especially useful for directly analyzing moderately complex samples. eng
dc.language.iso eng eng
dc.publisher Hannover : Institutionelles Repositorium der Leibniz Universität Hannover
dc.rights Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. eng
dc.subject.ddc 621,3 | Elektrotechnik, Elektronik eng
dc.title Improving ion mobility spectrometer sensitivity through an optimized sample gas flow eng
dc.type ConferenceObject eng
dc.type Text eng
dc.description.version publishedVersion eng
tib.accessRights frei zug�nglich eng


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken