Acoustic Feedback in Gait Rehabilitation—Pre-Post Effects in Patients With Unilateral Hip Arthroplasty

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/11176
dc.identifier.uri https://www.repo.uni-hannover.de/handle/123456789/11262
dc.contributor.author Reh, Julia
dc.contributor.author Schmitz, Gerd
dc.contributor.author Hwang, Tong-Hun
dc.contributor.author Effenberg, Alfred O.
dc.date.accessioned 2021-08-12T11:25:52Z
dc.date.available 2021-08-12T11:25:52Z
dc.date.issued 2021
dc.identifier.citation Reh, J.; Schmitz, G.; Hwang, T.-H.; Effenberg, A.O.: Acoustic Feedback in Gait Rehabilitation - Pre-Post Effects in Patients With Unilateral Hip Arthroplasty. In: Frontiers in Sports and Active Living 3 (2021), 654546. DOI: https://doi.org/10.3389/fspor.2021.654546
dc.description.abstract It is known that patients after unilateral hip arthroplasty still suffer from a deficient gait pattern compared to healthy individuals one year after surgery. Through the method of gait sonification, it may be possible to achieve a more efficient training and a more physiological gait pattern. Increased loads on the musculoskeletal system could thus be reduced and rehabilitation times shortened. In a previous investigation with this patient group, we found immediate gait pattern changes during training with dual mode acoustic feedback [real-time feedback (RTF) and instructive model sequences (IMS)]. To determine whether an effect persists without the immediate use of acoustic feedback, we analyze data from four times of testing. Following unilateral hip arthroplasty 22 patients participated in an intervention of ten gait training sessions of 20 min each. During gait training the sonification group (SG) (n = 11) received an acoustic feedback consisting of RTF and IMS compared to a control group (CG) (n = 11). Pre-test, intermediate test, post-test, and re-test were conducted using an inertial sensor-based motion analysis system. We found significant effects (α = 0.05) regarding step length and range of motion (RoM) of the hip joint. Step length of the affected leg increased in the SG from intermediate test to post-test but decreased in the CG [intermediate test: (SG) 0.63 m ± 0.12 m, (CG) 0.63 m ± 0.09 m; post-test: (SG) 0.66 m ± 0.11 m, (CG) 0.60 m ± 0.09 m]. However, from the post-test to the re-test a reverse development was observed [re-test: (SG) 0.63 m ± 0.10 m, (CG) 0.65 m ± 0.09 m]. Also, from post-test to re-test a decrease in the RoM of the unaffected hip for the SG but an increase for the CG could be observed [post-test: (SG) 44.10° ± 7.86°, (CG) 37.05° ± 7.21°; re-test: (SG) 41.73° ± 7.38°, (CG) 40.85° ± 9.28°]. Regarding further parameters, significant interactions in step duration as well as increases in stride length, gait speed, cadence, and a decrease in ground contact time from pre-test to re-test were observed for both groups. eng
dc.language.iso eng
dc.publisher Lausanne : Frontiers Media
dc.relation.ispartofseries Frontiers in Sports and Active Living 3 (2021)
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0/
dc.subject gait sonification eng
dc.subject hip arthroplasty eng
dc.subject acoustic feedback eng
dc.subject gait rehabilitation eng
dc.subject range of motion eng
dc.subject training intervention eng
dc.subject.ddc 796 | Sport ger
dc.title Acoustic Feedback in Gait Rehabilitation—Pre-Post Effects in Patients With Unilateral Hip Arthroplasty
dc.type Article
dc.type Text
dc.relation.essn 2624-9367
dc.relation.doi https://doi.org/10.3389/fspor.2021.654546
dc.bibliographicCitation.volume 3
dc.bibliographicCitation.firstPage 654546
dc.description.version publishedVersion
tib.accessRights frei zug�nglich