Comparative measurements of bone mineral density and bone contrast values in canine femora using dual-energy X-ray absorptiometry and conventional digital radiography

Download statistics - Document (COUNTER):

Lucas, K.; Nolte, I.; Galindo-Zamora, V.; Lerch, M.; Stukenborg-Colsman, C. et al.: Comparative measurements of bone mineral density and bone contrast values in canine femora using dual-energy X-ray absorptiometry and conventional digital radiography. In: BMC Veterinary Research 13 (2017), Nr. 1, 130. DOI: https://doi.org/10.1186/s12917-017-1047-y

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/1650

Selected time period:

year: 
month: 

Sum total of downloads: 133




Thumbnail
Abstract: 
Background: Aseptic loosening due to bone remodelling processes after total hip replacement is one common cause for revision surgery. In human medicine, dual-energy X-ray absorptiometry (DEXA) is the gold standard for quantitative evaluation of bone mineral density, whereas in veterinary medicine conventional radiography is used for follow-up studies. Recently, a method has been described using digital X-ray images for quantitative assessment of grey scale values of bone contrast. Therefore, the aim of the present study was to evaluate the correlation of bone mineral density (BMD) measured by DEXA with grey scale values (GV) measured in digital X-ray images (RX50, RX66) ex vivo. Results: The measured GV in the chosen X-ray settings showed on average a good correlation (r = 0.61) to the measured BMD with DEXA. Correlation between the two X-ray settings was very good (r = 0.81). For comparisons among regions of interests (ROIs) a difference of 8.2% was found to be statistically significant, whereas in the case of RX50 and RX66 differences of 5.3% and 4.1% were found to be statistically significant. Conclusions: Results indicate that measuring absolute changes in bone mineral density might be possible using digital radiography. Not all significant differences between ROIs detectable with DEXA can be displayed in the X-ray images because of the lower sensitivity of the radiographs. However, direct comparison of grey scale values of the periprosthetic femur in one individual patient during the follow-up period, in order to predict bone remodelling processes, should be possible, but with a lesser sensitivity than with DEXA. It is important that the same X-ray settings are chosen for each patient for follow-up studies.
License of this version: CC BY 4.0 Unported
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2017
Appears in Collections:Fakultät für Maschinenbau

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 90 67.67%
2 image of flag of United States United States 16 12.03%
3 image of flag of China China 6 4.51%
4 image of flag of Austria Austria 6 4.51%
5 image of flag of Vietnam Vietnam 4 3.01%
6 image of flag of Indonesia Indonesia 3 2.26%
7 image of flag of No geo information available No geo information available 2 1.50%
8 image of flag of Singapore Singapore 1 0.75%
9 image of flag of Norway Norway 1 0.75%
10 image of flag of Argentina Argentina 1 0.75%
    other countries 3 2.26%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse