Towards a hand-held, fast, and sensitive gas chromatograph-ion mobility spectrometer for detecting volatile compounds

Download statistics - Document (COUNTER):

Ahrens, A.; Zimmermann, S.: Towards a hand-held, fast, and sensitive gas chromatograph-ion mobility spectrometer for detecting volatile compounds. In: Analytical and Bioanalytical Chemistry 413 (2021), S. 1009-1016. DOI: https://doi.org/10.1007/s00216-020-03059-9

Repository version

To cite the version in the repository, please use this identifier: https://doi.org/10.15488/12699

Selected time period:

year: 
month: 

Sum total of downloads: 65




Thumbnail
Abstract: 
Ion mobility spectrometers can detect gaseous compounds at atmospheric pressure in the range of parts per trillion within a second. Due to their fast response times, high sensitivity, and limited instrumental effort, they are used in a variety of applications, especially as mobile or hand-held devices. However, most real-life samples are gas mixtures, which can pose a challenge for IMS with atmospheric pressure chemical ionization mainly due to competing gas-phase ionization processes. Therefore, we present a miniaturized drift tube IMS coupled to a compact gas chromatograph for pre-separation, built of seven bundled standard GC columns (Rtx-Volatiles, Restek GmbH) with 250 μm ID and 1.07 m in length. Such pre-separation significantly reduces chemical cross sensitivities caused by competing gas-phase ionization processes and adds orthogonality. Our miniaturized GC-IMS system is characterized with alcohols, halocarbons, and ketones as model substances, reaching detection limits down to 70 pptv with IMS averaging times of just 125 ms. It separates test mixtures of ketones and halocarbons within 180 s and 50 s, respectively. The IMS has a short drift length of 40.6 mm and reaches a high resolving power of RP = 68. [Figure not available: see fulltext.]. © 2020, The Author(s).
License of this version: CC BY 4.0 Unported
Document Type: Article
Publishing status: publishedVersion
Issue Date: 2020
Appears in Collections:Fakultät für Elektrotechnik und Informatik

distribution of downloads over the selected time period:

downloads by country:

pos. country downloads
total perc.
1 image of flag of Germany Germany 35 53.85%
2 image of flag of United States United States 13 20.00%
3 image of flag of China China 6 9.23%
4 image of flag of No geo information available No geo information available 2 3.08%
5 image of flag of Taiwan Taiwan 2 3.08%
6 image of flag of Indonesia Indonesia 2 3.08%
7 image of flag of Vietnam Vietnam 1 1.54%
8 image of flag of Ireland Ireland 1 1.54%
9 image of flag of Greece Greece 1 1.54%
10 image of flag of Europe Europe 1 1.54%
    other countries 1 1.54%

Further download figures and rankings:


Hinweis

Zur Erhebung der Downloadstatistiken kommen entsprechend dem „COUNTER Code of Practice for e-Resources“ international anerkannte Regeln und Normen zur Anwendung. COUNTER ist eine internationale Non-Profit-Organisation, in der Bibliotheksverbände, Datenbankanbieter und Verlage gemeinsam an Standards zur Erhebung, Speicherung und Verarbeitung von Nutzungsdaten elektronischer Ressourcen arbeiten, welche so Objektivität und Vergleichbarkeit gewährleisten sollen. Es werden hierbei ausschließlich Zugriffe auf die entsprechenden Volltexte ausgewertet, keine Aufrufe der Website an sich.

Search the repository


Browse