Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/3432
dc.identifier.uri http://www.repo.uni-hannover.de/handle/123456789/3462
dc.contributor.author Zuber, Ralf
dc.contributor.author Sperfeld, Peter
dc.contributor.author Riechelmann, Stefan
dc.contributor.author Nevas, Saulius
dc.contributor.author Sildoja, Meelis
dc.contributor.author Seckmeyer, Gunther
dc.date.accessioned 2018-06-08T11:57:12Z
dc.date.available 2018-06-08T11:57:12Z
dc.date.issued 2018
dc.identifier.citation Zuber, R.; Sperfeld, P.; Riechelmann, S.; Nevas, S.; Sildoja, M. et al.: Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range. In: Atmospheric Measurement Techniques 11 (2018), Nr. 4, S. 2477-2484. DOI: https://doi.org/10.5194/amt-11-2477-2018
dc.description.abstract A compact array spectroradiometer that enables precise and robust measurements of solar UV spectral direct irradiance is presented. We show that this instrument can retrieve total ozone column (TOC) accurately. The internal stray light, which is often the limiting factor for measurements in the UV spectral range and increases the uncertainty for TOC analysis, is physically reduced so that no other stray-light reduction methods, such as mathematical corrections, are necessary. The instrument has been extensively characterised at the Physikalisch-Technische Bundesanstalt (PTB) in Germany. During an international total ozone measurement intercomparison at the Izaña Atmospheric Observatory in Tenerife, the high-quality applicability of the instrument was verified with measurements of the direct solar irradiance and subsequent TOC evaluations based on the spectral data measured between 12 and 30 September 2016. The results showed deviations of the TOC of less than 1.5% from most other instruments in most situations and not exceeding 3% from established TOC measurement systems such as Dobson or Brewer. © 2018 Author(s). eng
dc.language.iso eng
dc.publisher Göttingen : Copernicus GmbH
dc.relation.ispartofseries Atmospheric Measurement Techniques 11 (2018), Nr. 4
dc.rights CC BY 4.0 Unported
dc.rights.uri https://creativecommons.org/licenses/by/4.0/
dc.subject limiting factor eng
dc.subject measurement method eng
dc.subject numerical method eng
dc.subject ozone eng
dc.subject radiometer eng
dc.subject reduction eng
dc.subject solar radiation eng
dc.subject spectrometer eng
dc.subject total ozone eng
dc.subject ultraviolet radiation eng
dc.subject Germany eng
dc.subject.ddc 550 | Geowissenschaften ger
dc.title Adaption of an array spectroradiometer for total ozone column retrieval using direct solar irradiance measurements in the UV spectral range eng
dc.type Article
dc.type Text
dc.relation.issn 1867-1381
dc.relation.doi https://doi.org/10.5194/amt-11-2477-2018
dc.bibliographicCitation.issue 4
dc.bibliographicCitation.volume 11
dc.bibliographicCitation.firstPage 2477
dc.bibliographicCitation.lastPage 2484
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken