Light section measurement to quantify the accuracy loss induced by laser light deflection in an inhomogeneous refractive index field

Zur Kurzanzeige

dc.identifier.uri http://dx.doi.org/10.15488/2035
dc.identifier.uri http://www.repo.uni-hannover.de/handle/123456789/2060
dc.contributor.author Beermann, Rüdiger
dc.contributor.author Quentin, Lorenz
dc.contributor.author Pösch, Andreas
dc.contributor.author Reithmeier, Eduard
dc.contributor.author Kästner, Markus
dc.date.accessioned 2017-10-12T08:42:49Z
dc.date.available 2017-10-12T08:42:49Z
dc.date.issued 2017
dc.identifier.citation Beermann, R.; Quentin, L.; Pösch, A.; Reithmeier, E.; Kästner, M.: Light section measurement to quantify the accuracy loss induced by laser light deflection in an inhomogeneous refractive index field. In: Proceedings of SPIE - The International Society for Optical Engineering 10329 (2017), 103292T. DOI: https://doi.org/10.1117/12.2269724
dc.description.abstract In the manufacturing process of Tailored Forming components, the inline inspection of the joining zone directly after each single process step can yield advantages - such as early error detection and real-time process control. Since measuring times need to be synchronized with the production chain, there is no time to cool down the components in between two hot forming processes. On the one hand, the chosen measurement technique needs to be non-tactile due to the heat of the measurement object. On the other hand, the object's areal surface texture needs to be captured rapidly to realize a fast inline inspection. These requirements are only matched by optical 3d measurement systems. Additional challenges arise due to the high temperature of the Tailored Forming components: The ambient air is heated up and the air's temperature increase results in an inhomogeneous refractive index field surrounding the hot workpiece, effecting the light's path emitted by the illumination unit of the optical sensor. We present a simple measurement setup based on the laser light section method to visualize the measurement accuracy loss induced by the convectional heat flow from a hot cylindrical measurement object. To attain a direct validation of the measurement results, the measurements are performed with and with reduced influence of the inhomogeneous refractive index field induced by the hot object. © 2017 SPIE. eng
dc.language.iso eng
dc.publisher Bellingham, Wash. : SPIE
dc.relation.ispartofseries Proceedings of SPIE 10329 (2017)
dc.rights Es gilt deutsches Urheberrecht. Das Dokument darf zum eigenen Gebrauch kostenfrei genutzt, aber nicht im Internet bereitgestellt oder an Außenstehende weitergegeben werden. Dieser Beitrag ist aufgrund einer (DFG-geförderten) Allianz- bzw. Nationallizenz frei zugänglich.
dc.subject 3D measurement eng
dc.subject laser light section eng
dc.subject light deection eng
dc.subject optics eng
dc.subject refractive index field eng
dc.subject Inspection eng
dc.subject Light eng
dc.subject Optical data processing eng
dc.subject Optical testing eng
dc.subject Optical variables measurement eng
dc.subject Optics eng
dc.subject 3-D measurement eng
dc.subject Laser light section eng
dc.subject Manufacturing process eng
dc.subject Measurement accuracy eng
dc.subject Measurement techniques eng
dc.subject Optical 3D-measurement eng
dc.subject Real-time process control eng
dc.subject Refractive index field eng
dc.subject Refractive index eng
dc.subject.classification Konferenzschrift ger
dc.subject.ddc 530 | Physik ger
dc.title Light section measurement to quantify the accuracy loss induced by laser light deflection in an inhomogeneous refractive index field
dc.type BookPart
dc.type Text
dc.relation.essn 1996-756X
dc.relation.isbn 978-1-5106-1104-7
dc.relation.issn 0277-786X
dc.relation.doi https://doi.org/10.1117/12.2269724
dc.bibliographicCitation.volume 10329
dc.bibliographicCitation.firstPage 103292T
dc.description.version publishedVersion
tib.accessRights frei zug�nglich


Die Publikation erscheint in Sammlung(en):

Zur Kurzanzeige

 

Suche im Repositorium


Durchblättern

Mein Nutzer/innenkonto

Nutzungsstatistiken