dc.identifier.uri |
http://dx.doi.org/10.15488/2033 |
|
dc.identifier.uri |
http://www.repo.uni-hannover.de/handle/123456789/2058 |
|
dc.contributor.author |
Sellner, S.
|
|
dc.contributor.author |
Besirli, M.
|
|
dc.contributor.author |
Bohman, M.
|
|
dc.contributor.author |
Borchert, M.J.
|
|
dc.contributor.author |
Harrington, J.
|
|
dc.contributor.author |
Higuchi, T.
|
|
dc.contributor.author |
Mooser, A.
|
|
dc.contributor.author |
Nagahama, H.
|
|
dc.contributor.author |
Schneider, G.
|
|
dc.contributor.author |
Smorra, C.
|
|
dc.contributor.author |
Tanaka, T.
|
|
dc.contributor.author |
Blaum, K.
|
|
dc.contributor.author |
Matsuda, Y.
|
|
dc.contributor.author |
Ospelkaus, C.
|
|
dc.contributor.author |
Quint, W.
|
|
dc.contributor.author |
Walz, J.
|
|
dc.contributor.author |
Yamazaki, Y.
|
|
dc.contributor.author |
Ulmer, S.
|
|
dc.date.accessioned |
2017-10-12T08:42:48Z |
|
dc.date.available |
2017-10-12T08:42:48Z |
|
dc.date.issued |
2017 |
|
dc.identifier.citation |
Sellner, S.; Besirli, M.; Bohman, M.; Borchert, M.J.; Harrington, J. et al.: Improved limit on the directly measured antiproton lifetime. In: New Journal of Physics 19 (2017), Nr. 8, 83023. DOI: https://doi.org/10.1088/1367-2630/aa7e73 |
|
dc.description.abstract |
Continuous monitoring of a cloud of antiprotons stored in a Penning trap for 405 days enables us to set an improved limit on the directly measured antiproton lifetime. From our measurements we extract a storage time of 3.15x108 equivalent antiproton-seconds, resulting in a lower lifetime limit of Tp > 10.2,a with a confidence level of 68%. This result improves the limit on charge-parity-time violation in antiproton decays based on direct observation by a factor of 7. |
eng |
dc.language.iso |
eng |
|
dc.publisher |
Bristol : Institute of Physics Publishing |
|
dc.relation.ispartofseries |
New Journal of Physics 19 (2017), Nr. 8 |
|
dc.rights |
CC BY 3.0 Unported |
|
dc.rights.uri |
https://creativecommons.org/licenses/by/3.0/ |
|
dc.subject |
antiprotons |
eng |
dc.subject |
CPT invariance |
eng |
dc.subject |
lifetimes |
eng |
dc.subject |
penning traps |
eng |
dc.subject |
Physics |
eng |
dc.subject |
antiprotons |
eng |
dc.subject |
Charge parity |
eng |
dc.subject |
Confidence levels |
eng |
dc.subject |
Continuous monitoring |
eng |
dc.subject |
CPT invariance |
eng |
dc.subject |
Direct observations |
eng |
dc.subject |
lifetimes |
eng |
dc.subject |
Penning trap |
eng |
dc.subject |
Research |
eng |
dc.subject.ddc |
530 | Physik
|
ger |
dc.title |
Improved limit on the directly measured antiproton lifetime |
|
dc.type |
Article |
|
dc.type |
Text |
|
dc.relation.issn |
1367-2630 |
|
dc.relation.doi |
https://doi.org/10.1088/1367-2630/aa7e73 |
|
dc.bibliographicCitation.issue |
8 |
|
dc.bibliographicCitation.volume |
19 |
|
dc.bibliographicCitation.firstPage |
83023 |
|
dc.description.version |
publishedVersion |
|
tib.accessRights |
frei zug�nglich |
|